Efficacy and safety of a self-expandable retainer in endoscopic ear surgery
European Archives of Oto-Rhino-Laryngology · 2024
DOI: 10.1007/s00405-024-08838-z ↗Kurz gefasst
Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, 2024. Verfasst von Yun Ji Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology-Head and Neck Surgery, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul…. Hauptthemen laut MEDLINE: Endoscopy, Tympanoplasty. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: During endoscopic ear surgery (EES), it is important to maintain a clear view of the endoscopic camera to achieve a clean field. In this study, a self-expandable external auditory canal (EAC) retainer was developed to enable a more efficient and safer EES. This study aimed to evaluate the retainer's efficacy and safety in EES. METHODS: Among adult patients scheduled for endoscopic tympanoplasty, 50 participants were recruited. They were assigned to either the retainer or control group in a 1:1 ratio. The anatomical characteristics, number of endoscopic cleanings during surgery, surgeon's satisfaction, and other factors were evaluated. RESULTS: No differences were observed in the surgical direction, EAC size measured on preoperative temporal bone computed tomography scans, location and size of tympanic membrane perforation, or bleeding degree between the two groups. When comparing the surgical time, including retainer insertion and removal, the time was similar between groups (retainer group, 35 min; control group, 33.2 min). The frequency of endoscopic cleaning per minute was statistically significantly lower in the retainer group than in the control group (0.18 times per minute, p = 0.048). No side effects, including sensory abnormalities or allergic reactions, were reported in any patient who used the retainer. CONCLUSION: A reduction in unnecessary endoscopic cleaning during EES was observed while using the self-expandable retainer, leading to increased surgeon satisfaction and efficiency. Furthermore, as a safe method without side effects, the retainer could be widely used to various indications for EES beyond tympanoplasty.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology-Head and Neck Surgery, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, Korea.
- Department of Otorhinolaryngology-Head and Neck Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
- Department of Otorhinolaryngology-Head and Neck Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. jwchung@amc.seoul.kr.
Zitieren
APA
Lee, Y. J., Kang, W. S., & Chung, J. W. (2024). Efficacy and safety of a self-expandable retainer in endoscopic ear surgery. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-024-08838-z
Vancouver
Lee YJ, Kang WS, Chung JW. Efficacy and safety of a self-expandable retainer in endoscopic ear surgery. European Archives of Oto-Rhino-Laryngology. 2024. doi:10.1007/s00405-024-08838-z
BibTeX
@article{Lee2024,
author = {Lee, Yun Ji and Kang, Woo Seok and Chung, Jong Woo},
title = {Efficacy and safety of a self-expandable retainer in endoscopic ear surgery},
journal = {European Archives of Oto-Rhino-Laryngology},
year = {2024},
doi = {10.1007/s00405-024-08838-z}
}
EUVIMED