EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Diagnostic Performance of Magnetic Resonance Elastography Versus Vibration‐Controlled Transient Elastography for Liver Fibrosis Staging in Steatotic Liver Disease

Leon David Gruenewald iD, Christian Booz, Jennifer Gotta iD, Philipp Reschke iD, Tommaso D'Angelo iD, Nicole Suarez Ziegengeist iD, Katerina Torgashov, Laura Hempfling iD, Scherwin Mahmoudi iD, Lisa Reisbeck iD, Renate Maria Hammerstingl, Stefan Zeuzem und 15 weitere

NMR in Biomedicine · 2026-12 · 39 (12)

DOI: 10.1002/nbm.70429 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift NMR in Biomedicine, online erschienen am 03.11.2026. Verfasst von Leon David Gruenewald und 26 weiteren Autor:innen. Beteiligte Einrichtung: Goethe University Frankfurt, University Hospital, Department of Radiology and Nuclear Medicine, Frankfurt am Main, Germany. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver Cirrhosis, Vibration, Magnetic Resonance Imaging. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Agency, SiRIC InsiTu: Insights into cancer: From inflammation to tumor, FHU MOSAIC2.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gravitational magnetic resonance elastography (GT‐MRE) enables comprehensive biomechanical liver characterization and may overcome limitations of conventional elastography techniques. This study evaluated the diagnostic performance of two‐ and three‐dimensional (2D and 3D) GT‐MRE compared with 2D acoustic MRE (AC‐MRE) and vibration‐controlled transient elastography (VCTE) for liver fibrosis staging. In this prospective study, patients with suspected or known steatotic liver disease underwent GT‐MRE (2D and 3D, gradient‐echo sequences) and AC‐MRE (2D, spin‐echo echo‐planar imaging) at 1.5 T, plus VCTE with a median interval to MRE of 37 days (IQR, 20–124 days; range, 0–372 days). Statistical analyses included generalized additive models, ordinal logistic regression, and decision tree‐based classification. Diagnostic performance was assessed using cumulative receiver operating characteristic analysis and corresponding areas under the curve (AUCs). Ninety‐one participants (median age, 55 years [IQR, 45–64]; 41 women) were included, of whom 35 (38%) had histopathological correlation. In the biopsy‐confirmed subgroup, 3D GT‐MRE‐derived viscoelastic parameters showed promising exploratory performance for early fibrosis classification. Wave attenuation achieved AUCs of 0.91 for F0 versus ≥ F1 and 0.99 for ≤ F1 versus ≥ F2, while phase angle yielded an AUC of 0.88 for F0 versus ≥ F1, with numerically higher AUCs than conventional stiffness‐based metrics. For advanced fibrosis thresholds, all modalities performed well (AUC ≥ 0.84). Obuchowski measures for 3D‐derived parameters were 0.95–0.96. Internally cross‐validated multiparametric modeling achieved an accuracy of up to 92%. VCTE measurements plateaued beyond F3, whereas AC‐ and GT‐MRE metrics continued to increase with fibrosis severity. 3D GT‐MRE‐derived viscoelastic parameters showed promising performance for liver fibrosis classification and provided biomechanical information complementary to conventional stiffness measurements. Given the limited biopsy‐confirmed sample and marked class imbalance at F0, these findings require validation in larger independent cohorts before clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesLiver CirrhosisVibrationMagnetic Resonance ImagingFatty LiverHumansFemaleMiddle AgedMaleROC Curve

Stichwörter der Autor:innen

gravitational transducermagnetic resonance elastographymagnetic resonance imagingmetabolic dysfunction‐associated steatohepatitistransient elastography

Autor:innen und Institutionen

  • Goethe University Frankfurt, University Hospital, Department of Radiology and Nuclear Medicine, Frankfurt am Main, Germany.
  • Goethe University Frankfurt, University Hospital, Department of Pediatrics, Frankfurt am Main, Germany.
  • Goethe University Frankfurt, University Hospital, Department of Internal Medicine I, Frankfurt am Main, Germany.
  • Goethe University Frankfurt, Faculty of Medicine, Institute of Biostatistics and Mathematical Modeling, Frankfurt am Main, Germany.
  • Goethe University Frankfurt, University Hospital, Department of Internal Medicine, Infectious Diseases, Frankfurt am Main, Germany.
  • University Hospital Jena, Institute of Diagnostic and Interventional Radiology, Section Neuroradiology, Jena, Germany.

ORCID-Profile: Leon David Gruenewald, Jennifer Gotta, Philipp Reschke, Tommaso D'Angelo, Nicole Suarez Ziegengeist, Laura Hempfling, Scherwin Mahmoudi, Lisa Reisbeck, Melis Onay, Eva Herrmann, Iulia Dahmer, Katharina Schregel, Ralph Sinkus, Sebastian Haberkorn, Vitali Koch

Förderung

  • National Research Agency
  • SiRIC InsiTu: Insights into cancer: From inflammation to tumor
  • FHU MOSAIC2
  • Bundesministerium für Forschung, Technologie und Raumfahrt
  • BMFTR
  • Doktor Robert Pfleger Foundation
  • Wilhelm Vaillant Foundation
  • Doktor Robert Pfleger-Stiftung

Zitieren

APA

Gruenewald, L. D., Booz, C., Gotta, J., Reschke, P., D'Angelo, T., Ziegengeist, N. S., Torgashov, K., Hempfling, L., Mahmoudi, S., Reisbeck, L., Hammerstingl, R. M., Zeuzem, S., Görgülü, E., Pathil-Warth, A., Onay, M., Herrmann, E., Dahmer, I., Idris, R., Vehreschild, M. J. G. T., …, & Koch, V. (2026). Diagnostic Performance of Magnetic Resonance Elastography Versus Vibration‐Controlled Transient Elastography for Liver Fibrosis Staging in Steatotic Liver Disease. NMR in Biomedicine, 39(12). https://doi.org/10.1002/nbm.70429

Vancouver

Gruenewald LD, Booz C, Gotta J, Reschke P, D'Angelo T, Ziegengeist NS, et al. Diagnostic Performance of Magnetic Resonance Elastography Versus Vibration‐Controlled Transient Elastography for Liver Fibrosis Staging in Steatotic Liver Disease. NMR in Biomedicine. 2026;39(12). doi:10.1002/nbm.70429

BibTeX
@article{Gruenewald2026,
  author = {Gruenewald, Leon David and Booz, Christian and Gotta, Jennifer and Reschke, Philipp and D'Angelo, Tommaso and Ziegengeist, Nicole Suarez and Torgashov, Katerina and Hempfling, Laura and Mahmoudi, Scherwin and Reisbeck, Lisa and Hammerstingl, Renate Maria and Zeuzem, Stefan and Görgülü, Esra and Pathil-Warth, Anita and Onay, Melis and Herrmann, Eva and Dahmer, Iulia and Idris, Raja and Vehreschild, Maria Johanna Gobertina Tetuanui and Schregel, Katharina and Sommer, Christof Matthias and Ciesek, Sandra and Eichler, Katrin and Vogl, Thomas Joseph and Sinkus, Ralph and Haberkorn, Sebastian and Koch, Vitali},
  title = {Diagnostic Performance of Magnetic Resonance Elastography Versus Vibration‐Controlled Transient Elastography for Liver Fibrosis Staging in Steatotic Liver Disease},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {12},
  doi = {10.1002/nbm.70429}
}
Kostenlos starten →