Optimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis
Clinical and Molecular Hepatology · 30.09.2024 · 30 (Suppl) · S117-S133
DOI: 10.3350/cmh.2024.0392 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Clinical and Molecular Hepatology, erschienen am 30.09.2024. Verfasst von Young Eun Chon und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, CHA Bundang Medical Center, CHA University, Seongnam, Korea. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver, Liver Cirrhosis, Non-alcoholic Fatty Liver Disease. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 102 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Background/aims: Opinions differ regarding vibration-controlled transient elastography and magnetic resonance elastography (VCTE/MRE) cut-offs for diagnosing advanced fibrosis (AF) in patients with non-alcoholic fatty liver disease (NAFLD). We investigated the diagnostic performance and optimal cut-off values of VCTE and MRE for diagnosing AF.
Methods
Literature databases, including Medline, EMBASE, Cochrane Library, and KoreaMed, were used to identify relevant studies published up to June 13, 2023. We selected studies evaluating VCTE and MRE regarding the degree of liver fibrosis using liver biopsy as the reference. The sensitivity, specificity, and area under receiver operating characteristics curves (AUCs) of the pooled data for VCTE and MRE for each fibrosis stage and optimal cut-offs for AF were investigated.
Results
A total of 19,199 patients from 63 studies using VCTE showed diagnostic AUC of 0.83 (95% confidence interval: 0.80–0.86), 0.83 (0.80–0.86), 0.87 (0.84–0.90), and 0.94 (0.91–0.96) for ≥F1, ≥F2, ≥F3, and F4 stages, respectively. Similarly, 1,484 patients from 14 studies using MRE showed diagnostic AUC of 0.89 (0.86–0.92), 0.92 (0.89–0.94), 0.89 (0.86–0.92), and 0.94 (0.91–0.96) for ≥F1, ≥F2, ≥F3, and F4 stages, respectively. The diagnostic AUC for AF using VCTE was highest at 0.90 with a cut-off of 7.1–7.9 kPa, and that of MRE was highest at 0.94 with a cut-off of 3.62–3.8 kPa.
Conclusions
VCTE (7.1–7.9 kPa) and MRE (3.62–3.8 kPa) with the suggested cut-offs showed favorable accuracy for diagnosing AF in patients with NAFLD. This result will serve as a basis for clinical guidelines for non-invasive tests and differential diagnosis of AF.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, CHA Bundang Medical Center, CHA University, Seongnam, Korea.
- Department of Internal Medicine, Inha University Hospital, Inha University School of Medicine, Incheon, Korea.
- Department of Gastroenterology and Hepatology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea.
- Department of Internal Medicine, College of Medicine, Bucheon St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea.
- Division of Health Technology Assessment Research, National Evidence-Based Healthcare Collaborating Agency (NECA), Seoul, Korea.
- Department of Internal Medicine, Hanyang University Hospital, Hanyang University College of Medicine, Seoul, Korea.
Zitieren
APA
Chon, Y. E., Jin, Y. J., An, J., Kim, H. Y., Choi, M., Jun, D. W., Kim, M. N., Han, J. W., Lee, H. A., Yu, J. H., & Kim, S. U. (2024). Optimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis. Clinical and Molecular Hepatology, 30(Suppl), S117-S133. https://doi.org/10.3350/cmh.2024.0392
Vancouver
Chon YE, Jin YJ, An J, Kim HY, Choi M, Jun DW, et al. Optimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis. Clinical and Molecular Hepatology. 2024;30(Suppl):S117-S133. doi:10.3350/cmh.2024.0392
BibTeX
@article{Chon2024,
author = {Chon, Young Eun and Jin, Young-Joo and An, Jihyun and Kim, Hee Yeon and Choi, Miyoung and Jun, Dae Won and Kim, Mi Na and Han, Ji Won and Lee, Han Ah and Yu, Jung Hwan and Kim, Seung Up},
title = {Optimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis},
journal = {Clinical and Molecular Hepatology},
year = {2024},
volume = {30},
number = {Suppl},
pages = {S117--S133},
doi = {10.3350/cmh.2024.0392}
}
EUVIMED