Repeatability of vibration‐controlled transient elastography versus magnetic resonance elastography in patients with cirrhosis: A prospective study
Alimentary Pharmacology & Therapeutics · 2024
DOI: 10.1111/apt.18118 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Alimentary Pharmacology & Therapeutics, 2024. Verfasst von Harris Siddiqi und 10 weiteren Autor:innen. Beteiligte Einrichtung: MASLD Research Center, Division of Gastroenterology, University of California at San Diego, La Jolla, California, USA. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver Cirrhosis, Vibration. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS, NCATS NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Background and Aims Magnetic resonance elastography (MRE) and vibration‐controlled transient elastography (VCTE) have the potential to assess disease progression; however, repeatability data in people with cirrhosis are lacking. We aimed to assess the effect of disease severity on measurement variability and contribute to the evidentiary basis for the qualification of repeating liver stiffness measurements (LSM) in practice and research.
Methods
This prospective study included 49 adult participants (58.3% female) with cirrhosis who underwent same‐day repeat LSM examinations. The primary outcome was the same‐day, same‐operator repeatability coefficient% (RC%) and the within‐case coefficient of variation (wCV) for each modality. Secondary outcomes include the intra‐class correlation coefficient (ICC). The relationship between measurement variability (interquartile for VCTE, standard deviation for MRE) and disease severity (mean liver stiffness) was evaluated by linear regression with the coefficient of determination R 2 reported.
Results
Same‐day repeat MRE and VCTE exams were prospectively conducted in 33 and 45 participants, respectively. The RC% appeared 82% higher for VCTE versus MRE (38% vs. 21%), with consistent findings in head‐to‐head analyses. The wCV for VCTE and MRE was 14% and 8% respectively, indicating VCTE has 75% higher within‐subject measurement variation than MRE. ICC was excellent for LSM by VCTE (0.92) and MRE (0.96). Measurement variability increased with mean liver stiffness for VCTE ( R 2 = 0.78) and MRE ( R 2 = 0.93).
Conclusion
Both VCTE and MRE demonstrated increased measurement variability with disease severity. However, MRE outperformed VCTE in terms of technical repeatability in patients with cirrhosis. These repeatability estimates may improve the qualification of NITs in practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- MASLD Research Center, Division of Gastroenterology, University of California at San Diego, La Jolla, California, USA.
- Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
- Liver Imaging Group, University of California at San Diego, La Jolla, California, USA.
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
- Division of Gastroenterology and Hepatology, University of California at San Diego, La Jolla, California, USA.
ORCID-Profile: Daniel Q Huang
Förderung
- NIDDK NIH HHS
- NCATS NIH HHS
- NIBIB NIH HHS
- NHLBI NIH HHS
- Singapore Ministry of Health's National Medical Research Council
- National Institute of Biomedical Imaging and Bioengineering
- National Heart, Lung, and Blood Institute
- National Institute of Diabetes and Digestive and Kidney Diseases
Zitieren
APA
Siddiqi, H., Huang, D. Q., Mittal, N., Nourredin, N., Bettencourt, R., Madamba, E., Amangurbanova, M., Hernandez, C., Sirlin, C., Yin, M., & Loomba, R. (2024). Repeatability of vibration‐controlled transient elastography versus magnetic resonance elastography in patients with cirrhosis: A prospective study. Alimentary Pharmacology & Therapeutics. https://doi.org/10.1111/apt.18118
Vancouver
Siddiqi H, Huang DQ, Mittal N, Nourredin N, Bettencourt R, Madamba E, et al. Repeatability of vibration‐controlled transient elastography versus magnetic resonance elastography in patients with cirrhosis: A prospective study. Alimentary Pharmacology & Therapeutics. 2024. doi:10.1111/apt.18118
BibTeX
@article{Siddiqi2024,
author = {Siddiqi, Harris and Huang, Daniel Q and Mittal, Nikita and Nourredin, Nabil and Bettencourt, Ricki and Madamba, Egbert and Amangurbanova, Maral and Hernandez, Christie and Sirlin, Claude and Yin, Meng and Loomba, Rohit},
title = {Repeatability of vibration‐controlled transient elastography versus magnetic resonance elastography in patients with cirrhosis: A prospective study},
journal = {Alimentary Pharmacology & Therapeutics},
year = {2024},
doi = {10.1111/apt.18118}
}
EUVIMED