Adaptively Optimized Combination of Phased‐Array MR Spectroscopy Data Without Noise Correlation Estimation: A Joint Diagonalization Method
NMR in Biomedicine · 2026
DOI: 10.1002/nbm.70371 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2026. Verfasst von Liang Fang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Psychiatry, University of Pittsburgh, Pittsburgh, Pennsylvania, USA. Hauptthemen laut MEDLINE: Signal-To-Noise Ratio, Algorithms. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIMH NIH HHS, NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
The adaptively optimized combination (AOC) method optimally combines multichannel magnetic resonance spectroscopy (MRS) data by incorporating noise correlations among receive coil elements/channels. These correlations are typically estimated from noise samples extracted from the fully decayed tails of acquired free induction decays (FIDs). To eliminate the need for FID noise tails and the corresponding interchannel noise correlation estimation, we propose a novel coil‐combination method, termed AOC‐JD, that exploits the intrinsic multichannel noise information contained in the differences between individual repetitions and the repetition‐averaged spectroscopic data. The proposed method is based on joint diagonalization (JD) of two correlation matrices constructed from the individual repetitions and the repetition‐averaged multichannel MRS data, thereby circumventing the conventional interchannel noise correlation estimation procedure. The performance of AOC‐JD was evaluated using both computer simulations and in vivo human brain experiments. The results demonstrate that, when multichannel FIDs do not contain valid or sufficiently long noise tails, AOC‐JD significantly improves the signal‐to‐noise ratio (SNR) of the combined spectra compared with the conventional singular value decomposition (SVD) method. Moreover, its performance is comparable to that of the original AOC method, which is optimized to maximize the SNR of the combined spectrum, when applicable. These findings demonstrate that AOC‐JD provides a theoretically grounded and reliable approach for combining multichannel MRS data when FID noise tails are unavailable or insufficient.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
- Department of Psychiatry, University of Illinois at Chicago, Chicago, Illinois, USA.
ORCID-Profile: Liang Fang, Minjie Wu, Howard J Aizenstein, Shaolin Yang
Förderung
- NIMH NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Fang, L., Wu, M., Aizenstein, H. J., Kumar, A., & Yang, S. (2026). Adaptively Optimized Combination of Phased‐Array MR Spectroscopy Data Without Noise Correlation Estimation: A Joint Diagonalization Method. NMR in Biomedicine. https://doi.org/10.1002/nbm.70371
Vancouver
Fang L, Wu M, Aizenstein HJ, Kumar A, Yang S. Adaptively Optimized Combination of Phased‐Array MR Spectroscopy Data Without Noise Correlation Estimation: A Joint Diagonalization Method. NMR in Biomedicine. 2026. doi:10.1002/nbm.70371
BibTeX
@article{Fang2026,
author = {Fang, Liang and Wu, Minjie and Aizenstein, Howard J and Kumar, Anand and Yang, Shaolin},
title = {Adaptively Optimized Combination of Phased‐Array MR Spectroscopy Data Without Noise Correlation Estimation: A Joint Diagonalization Method},
journal = {NMR in Biomedicine},
year = {2026},
doi = {10.1002/nbm.70371}
}
EUVIMED