EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Frequency and phase correction of GABA-edited magnetic resonance spectroscopy using complex-valued convolutional neural networks

Hanna Bugler, Rodrigo Berto, Roberto Souza, Ashley D Harris

Magnetic Resonance Imaging · 2024

DOI: 10.1016/j.mri.2024.05.008 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Hanna Bugler und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Calgary, Canada; Department of Radiology, University of Calgary, Canada; Hotchkiss Brain Institut…. Hauptthemen laut MEDLINE: gamma-Aminobutyric Acid, Neural Networks, Computer, Magnetic Resonance Spectroscopy, Signal-To-Noise Ratio. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To determine the significance of complex-valued inputs and complex-valued convolutions compared to real-valued inputs and real-valued convolutions in convolutional neural networks (CNNs) for frequency and phase correction (FPC) of GABA-edited magnetic resonance spectroscopy (MRS) data. METHODS: An ablation study using simulated data was performed to determine the most effective input (real or complex) and convolution type (real or complex) to predict frequency and phase shifts in GABA-edited MEGA-PRESS data using CNNs. The best CNN model was subsequently compared using both simulated and in vivo data to two recently proposed deep learning (DL) methods for FPC of GABA-edited MRS. All methods were trained using the same experimental setup and evaluated using the signal-to-noise ratio (SNR) and linewidth of the GABA peak, choline artifact, and by visually assessing the reconstructed final difference spectrum. Statistical significance was assessed using the Wilcoxon signed rank test. RESULTS: The ablation study showed that using complex values for the input represented by real and imaginary channels in our model input tensor, with complex convolutions was most effective for FPC. Overall, in the comparative study using simulated data, our CC-CNN model (that received complex-valued inputs with complex convolutions) outperformed the other models as evaluated by the mean absolute error. CONCLUSION: Our results indicate that the optimal CNN configuration for GABA-edited MRS FPC uses a complex-valued input and complex convolutions. Overall, this model outperformed existing DL models.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

gamma-Aminobutyric AcidNeural Networks, ComputerMagnetic Resonance SpectroscopySignal-To-Noise RatioHumansBrainDeep LearningAlgorithmsArtifactsCholineComputer Simulation

Stichwörter der Autor:innen

1H spectroscopyConvolutional neural networks (CNN)Frequency and phase correctionGABA-edited MRSMachine learningPre-processing

Substanzen

gamma-Aminobutyric AcidCholine

Autor:innen und Institutionen

  • Department of Biomedical Engineering, University of Calgary, Canada; Department of Radiology, University of Calgary, Canada; Hotchkiss Brain Institute, University of Calgary,Canada; Alberta Children's Hospital Research…
  • Hotchkiss Brain Institute, University of Calgary,Canada; Department of Electrical and Software Engineering, University of Calgary, Canada.
  • Department of Radiology, University of Calgary, Canada; Hotchkiss Brain Institute, University of Calgary,Canada; Alberta Children's Hospital Research Institute, University of Calgary, Canada.

Zitieren

APA

Bugler, H., Berto, R., Souza, R., & Harris, A. D. (2024). Frequency and phase correction of GABA-edited magnetic resonance spectroscopy using complex-valued convolutional neural networks. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.05.008

Vancouver

Bugler H, Berto R, Souza R, Harris AD. Frequency and phase correction of GABA-edited magnetic resonance spectroscopy using complex-valued convolutional neural networks. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.05.008

BibTeX
@article{Bugler2024,
  author = {Bugler, Hanna and Berto, Rodrigo and Souza, Roberto and Harris, Ashley D},
  title = {Frequency and phase correction of GABA-edited magnetic resonance spectroscopy using complex-valued convolutional neural networks},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.05.008}
}