EUVIMEDEUVIMED entdecken
Open Access

Repeatability of Simultaneous 1H/23Na MR Fingerprinting in Knee Cartilage at 7 T

Anne Adlung, Dimitri Martel iD, Baptiste Busi, Zidan Yu, Gonzalo Gabriel Rodriguez, Lauren F O'Donnell, Thorsten Kirsch, Martijn Cloos, Amparo Ruiz, Guillaume Madelin

NMR in Biomedicine · 2026-07 · 39 (7)

DOI: 10.1002/nbm.70321 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 16.06.2026. Verfasst von Anne Adlung und 9 weiteren Autor:innen. Beteiligte Einrichtung: Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New Yor…. Hauptthemen laut MEDLINE: Sodium, Cartilage, Articular, Magnetic Resonance Imaging, Knee Joint. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAMS NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluates the repeatability of a 3D simultaneous H/Na MR fingerprinting (MRF) sequence in knee cartilage of healthy volunteers. Eight healthy volunteers underwent four knee scans each with 3D simultaneous H/Na MRF at 7 T. Proton density (PD), tissue sodium concentration (TSC), and H and Na relaxation time maps were acquired over two visits with two consecutive acquisitions at both visits. Mean values and standard deviations of all MRF metrics were measured in three knee cartilage regions: patellar, femorotibial medial, and femorotibial lateral. Image processing included H and Na MRF dictionary matching, B correction, TSC and PD quantification, and image registration between the scans. Repeatability was assessed using the coefficient of variation (CV) and intraclass correlation coefficient (ICC) for all measurements and Bland–Altman plots to compare intraday and interday measurement differences. Mean TSC values over all subjects and cartilage regions were 162 29 mM, with a CV of 12% 1%. Mean Na T (30 2 ms) and T (13 3 ms) values were relatively consistent (CV = 6%–19%), while T showed greater variability (1.62 1.60 ms, CV = 54% 11%). For H, mean PD was 0.87 0.24 (CV = 20% 8%), mean T was 1114 168 ms (CV = 11% 5%), and mean T was 36 15 (CV = 20% 7%). ICC values suggested low‐to‐moderate discrimination power, with highest values observed for H T and lowest values for Na relaxation times. The Bland–Altman plots suggest similar intraday and interday differences. This study shows that we can acquire quantitative H and Na MRF maps simultaneously in knee cartilage at 7 T. Repeatability was the highest for TSC and Na T. ICC was the highest for PD and H T.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SodiumCartilage, ArticularMagnetic Resonance ImagingKnee JointHumansReproducibility of ResultsMaleAdultFemaleYoung AdultProtons

Stichwörter der Autor:innen

cartilagemagnetic resonance fingerprintingmultinuclearsimultaneoussodium

Substanzen

SodiumProtons

Autor:innen und Institutionen

  • Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • Tech4Health Institute, NYU Langone Health, New York, New York, USA.
  • Vilcek Institute for Graduate Biomedical Studies, NYU Langone Health, New York, New York, USA.
  • Philips, Best, the Netherlands.
  • NMR Signal Enhancement, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
  • Department of Orthopedic Surgery, New York University Grossman School of Medicine, New York, New York, USA.

ORCID-Profile: Dimitri Martel

Förderung

  • NIAMS NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Adlung, A., Martel, D., Busi, B., Yu, Z., Rodriguez, G. G., O'Donnell, L. F., Kirsch, T., Cloos, M., Ruiz, A., & Madelin, G. (2026). Repeatability of Simultaneous 1H/23Na MR Fingerprinting in Knee Cartilage at 7 T. NMR in Biomedicine, 39(7). https://doi.org/10.1002/nbm.70321

Vancouver

Adlung A, Martel D, Busi B, Yu Z, Rodriguez GG, O'Donnell LF, et al. Repeatability of Simultaneous 1H/23Na MR Fingerprinting in Knee Cartilage at 7 T. NMR in Biomedicine. 2026;39(7). doi:10.1002/nbm.70321

BibTeX
@article{Adlung2026,
  author = {Adlung, Anne and Martel, Dimitri and Busi, Baptiste and Yu, Zidan and Rodriguez, Gonzalo Gabriel and O'Donnell, Lauren F and Kirsch, Thorsten and Cloos, Martijn and Ruiz, Amparo and Madelin, Guillaume},
  title = {Repeatability of Simultaneous 1H/23Na MR Fingerprinting in Knee Cartilage at 7 T},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {7},
  doi = {10.1002/nbm.70321}
}
Kostenlos starten →