EUVIMEDEUVIMED entdecken
Crossref

A Mixed Single‐Echo and Multiecho MyoFoldstar for Simultaneous Quantification of Myocardial T 1 , T 2 , T 2 *, and Wall Motion

Rui Guo iD, Guozhao Dong, Bowei Liu, Yu Lian, Yifei Jiang, Xiaomeng Yang iD, Peng Wu iD, Yingwei Fan, Ancong Wang, Jingjing Xiao, Haiyan Ding iD, Xiaoying Tang

NMR in Biomedicine · 2026-07 · 39 (7)

DOI: 10.1002/nbm.70320 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 28.05.2026. Verfasst von Rui Guo und 11 weiteren Autor:innen. Beteiligte Einrichtung: School of Medical Technology, Beijing Institute of Technology, Beijing, China. Hauptthemen laut MEDLINE: Heart, Magnetic Resonance Imaging, Cine. Die Arbeit nennt 50 Literaturangaben. Gefördert von: Beijing Municipal Natural Science Foundation, Beijing Institute of Technology Research Fund Program for Young Scholars, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to propose a mixed single‐echo and multiecho MyoFoldstar sequence enabling simultaneous myocardial multiparametric mapping and wall‐motion quantification. MyoFoldstar is designed as a 2D, single breath‐holding sequence that sequentially performs joint T 1 / T 2 mapping, T 2 * mapping, and cine imaging within 17 heartbeats, using a golden‐angle radial gradient‐echo (GRE) readout and ECG synchronization. The joint T 1 / T 2 mapping collects seven single‐shot, single‐echo images on the first seven heartbeats with inversion and T 2 preparation ( T 2 prep). The subsequent T 2 * mapping acquires multishot, multiecho data over six heartbeats, followed by segmented cine with a single‐echo readout over four heartbeats. In vivo feasibility was demonstrated in 12 healthy volunteers at 3 T and compared with conventional single‐task sequences (MOLLI and SASHA for T 1 , T 2 prep bSSFP for T 2 , and BB‐meGRE for T 2 *). Accuracy was validated in phantom studies. Both in vivo and phantom studies demonstrated the feasibility of MyoFoldstar for simultaneously acquiring cardiac T 1 , T 2 , T 2 *, and cine imaging. MyoFoldstar‐derived myocardial T 1 (1521 ± 102 ms), T 2 (43.2 ± 3.0 ms), and T 2 * (19.2 ± 2.4 ms) showed good agreement with values from conventional single‐task sequences ( T 1 : 1248 ± 35 ms by MOLLI and 1580 ± 38 ms by SASHA; T 2 : 43.5 ± 2.2 ms by T 2 prep bSSFP; T 2 *: 23.4 ± 2.6 ms by BB‐meGRE). Compared with conventional cine, MyoFoldstar images exhibited reduced myocardium–blood contrast, yet left ventricular function quantifications were mainly preserved ( r > 0.9). Phantom results indicated that MyoFoldstar achieves good accuracy relative to reference standards. MyoFoldstar enables rapid myocardial T 1 , T 2 , T 2 *, and cine imaging within a single breath‐hold scan, delivering a time‐saving and comprehensive assessment of cardiovascular magnetization resonance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HeartMagnetic Resonance Imaging, CineHumansPhantoms, ImagingReproducibility of ResultsMovementMaleFemaleImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

breath holdingcardiac multiparametric mappingcinegolden‐angle radial

Autor:innen und Institutionen

  • School of Medical Technology, Beijing Institute of Technology, Beijing, China.
  • Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
  • Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
  • Philips Healthcare, Shanghai, China.
  • Bio-Med Informatics Research Centre and Clinical Research Centre, Xinqiao Hospital, Army Medical University, Chongqing, China.

ORCID-Profile: Rui Guo, Xiaomeng Yang, Peng Wu, Haiyan Ding

Förderung

  • Beijing Municipal Natural Science Foundation
  • Beijing Institute of Technology Research Fund Program for Young Scholars
  • National Natural Science Foundation of China

Zitieren

APA

Guo, R., Dong, G., Liu, B., Lian, Y., Jiang, Y., Yang, X., Wu, P., Fan, Y., Wang, A., Xiao, J., Ding, H., & Tang, X. (2026). A Mixed Single‐Echo and Multiecho MyoFoldstar for Simultaneous Quantification of Myocardial T 1 , T 2 , T 2 *, and Wall Motion. NMR in Biomedicine, 39(7). https://doi.org/10.1002/nbm.70320

Vancouver

Guo R, Dong G, Liu B, Lian Y, Jiang Y, Yang X, et al. A Mixed Single‐Echo and Multiecho MyoFoldstar for Simultaneous Quantification of Myocardial T 1 , T 2 , T 2 *, and Wall Motion. NMR in Biomedicine. 2026;39(7). doi:10.1002/nbm.70320

BibTeX
@article{Guo2026,
  author = {Guo, Rui and Dong, Guozhao and Liu, Bowei and Lian, Yu and Jiang, Yifei and Yang, Xiaomeng and Wu, Peng and Fan, Yingwei and Wang, Ancong and Xiao, Jingjing and Ding, Haiyan and Tang, Xiaoying},
  title = {A Mixed Single‐Echo and Multiecho MyoFoldstar for Simultaneous Quantification of Myocardial T 1 , T 2 , T 2 *, and Wall Motion},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {7},
  doi = {10.1002/nbm.70320}
}
Kostenlos starten →