EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

MRI Goes Mobile: Assessing the Reliability and Repeatability of a Mobile vs. Stationary 1.5 T MRI for Functional Neuroscience Studies

Christoph Stefan Aigner, Caroline Garcia Forlim iD, Davide Santoro, Nils C Bodammer, Rüdiger Brühl, Sonja Sudimac, Katharina Schmalen, Sebastian Schröder, Siawoosh Mohammadi, Simone Kühn

NMR in Biomedicine · 2026-07 · 39 (7)

DOI: 10.1002/nbm.70310 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift NMR in Biomedicine, online erschienen am 01.06.2026. Verfasst von Christoph Stefan Aigner und 9 weiteren Autor:innen. Beteiligte Einrichtung: Max Planck Research Group MR Physics, Max Planck Institute for Human Development, Berlin, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Neurosciences. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council, German Research Foundation, Emmy Noether Stipend.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mobile MRI scanners could transform neuroimaging by expanding accessibility to diverse populations and enabling data collection in remote settings. This study serves as a short‐term feasibility and system commissioning report, investigating the reliability and repeatability of two mobile 1.5 T MRI scanners compared to a stationary 1.5 T reference. To evaluate the technical impact of scanner relocation and mobile housing, a comprehensive protocol was implemented: five healthy subjects underwent 10 scans each ( N = 50 total sessions) across three 1.5 T systems (one stationary; two mobile). The protocol employed a test–retest design with participant repositioning on each measurement day. Stability was assessed through longitudinal fBIRN phantom scans and human imaging of magnetic field homogeneity (ΔB 0 ), RF flip‐angle mapping (B 1 + ), structural MP‐RAGE, and functional EPI‐BOLD. Initial commissioning results demonstrated that short‐term relocation and mobile operation did not compromise hardware performance. Phantom QA showed stable tSNR and minimal signal drift. In human subjects, magnetic field stability (ΔB 0 ) and B 1 + distributions were equivalent across systems, with Bland–Altman plots confirming no systematic bias following transit. Structural MP‐RAGE voxel‐intensity distributions and tissue volumes were highly consistent, with ICCs between 0.99 and 1 for estimated WM and GM volumes. This technical validation study demonstrates the short‐term feasibility of utilizing mobile 1.5 T platforms for high‐quality neuroimaging. The results confirm that current mobile shielding and stabilization technologies effectively mitigate the environmental challenges of transit, establishing a reliable baseline for future longitudinal research in remote or underserved settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingNeurosciencesHumansReproducibility of ResultsPhantoms, ImagingAdultMaleBrainFemale

Stichwörter der Autor:innen

1.5 T MRIenvironmental neurosciencemobile MRIreproducibilityresting‐state fMRI

Autor:innen und Institutionen

  • Max Planck Research Group MR Physics, Max Planck Institute for Human Development, Berlin, Germany.
  • Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany.
  • Center for Environmental Neuroscience, Max Planck Institute for Human Development, Berlin, Germany.
  • Scientific Technology & Computing, Max Planck Institute for Human Development, Berlin, Germany.
  • Advanced MRI Research, Department of Neuroradiology, University to Lübeck, Lübeck, Germany.
  • Department of Psychiatry and Psychotherapy, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.

ORCID-Profile: Caroline Garcia Forlim

Förderung

  • European Research Council
  • German Research Foundation
  • Emmy Noether Stipend

Zitieren

APA

Aigner, C. S., Forlim, C. G., Santoro, D., Bodammer, N. C., Brühl, R., Sudimac, S., Schmalen, K., Schröder, S., Mohammadi, S., & Kühn, S. (2026). MRI Goes Mobile: Assessing the Reliability and Repeatability of a Mobile vs. Stationary 1.5 T MRI for Functional Neuroscience Studies. NMR in Biomedicine, 39(7). https://doi.org/10.1002/nbm.70310

Vancouver

Aigner CS, Forlim CG, Santoro D, Bodammer NC, Brühl R, Sudimac S, et al. MRI Goes Mobile: Assessing the Reliability and Repeatability of a Mobile vs. Stationary 1.5 T MRI for Functional Neuroscience Studies. NMR in Biomedicine. 2026;39(7). doi:10.1002/nbm.70310

BibTeX
@article{Aigner2026,
  author = {Aigner, Christoph Stefan and Forlim, Caroline Garcia and Santoro, Davide and Bodammer, Nils C and Brühl, Rüdiger and Sudimac, Sonja and Schmalen, Katharina and Schröder, Sebastian and Mohammadi, Siawoosh and Kühn, Simone},
  title = {MRI Goes Mobile: Assessing the Reliability and Repeatability of a Mobile vs. Stationary 1.5 T MRI for Functional Neuroscience Studies},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {7},
  doi = {10.1002/nbm.70310}
}
Kostenlos starten →