EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Optimal Control‐Based Generic Framework for Radiofrequency Pulse Design in MRI

Emilio Molina iD, Hélène Ratiney iD, Eric Van Reeth iD

NMR in Biomedicine · 2026-06 · 39 (6)

DOI: 10.1002/nbm.70307 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 08.05.2026. Verfasst von Emilio Molina und 2 weiteren Autor:innen. Beteiligte Einrichtung: INSA-Lyon, Université Claude Bernard Lyon 1, CREATIS UMR CNRS 5220, Inserm U1294, Lyon, France. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Radio Waves, Signal Processing, Computer-Assisted. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: ANR, Agence Nationale de la Recherche.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work proposes a general framework for the optimal design of radiofrequency pulses in MRI. Based on optimal control theory, it proposes a Python‐based numerical implementation using state‐of‐the‐art nonlinear optimization solver (IPOPT). This study proposes three main contributions. It allows the incorporation of hard constraints to the problem and their consistent integration into the optimization process. It proposes to express the pulse as wavelet coefficients which proves to be highly effective in an applicative context. Finally, an innovative approach to minimize the pulse peak amplitude is presented by taking advantage of the efficient constraint management. The proposed framework is made available through a Python package, along with Jupyter Notebooks to reproduce the paper results. It also allows external users to solve their own design problem, benefiting from the generality and flexibility of the proposed implementation. The efficacy of the proposed method is validated in the context of short‐ selective excitation and ‐robust problems, with a primary focus on power and energy minimization. The optimized pulses provide a substantial enhancement regarding the compromise between energy/peak power and overall pulse performances, when compared to state‐of‐the‐art solutions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingRadio WavesSignal Processing, Computer-AssistedAlgorithms

Stichwörter der Autor:innen

MRIRF pulsesadiabatic pulsesoptimal controlshort‐ T 2 $$ {T}_2 $$ excitation

Autor:innen und Institutionen

  • INSA-Lyon, Université Claude Bernard Lyon 1, CREATIS UMR CNRS 5220, Inserm U1294, Lyon, France.
  • CPE Lyon, Villeurbanne, France.

ORCID-Profile: Emilio Molina, Hélène Ratiney, Eric Van Reeth

Förderung

  • ANR
  • Agence Nationale de la Recherche

Zitieren

APA

Molina, E., Ratiney, H., & Van Reeth, E. (2026). Optimal Control‐Based Generic Framework for Radiofrequency Pulse Design in MRI. NMR in Biomedicine, 39(6). https://doi.org/10.1002/nbm.70307

Vancouver

Molina E, Ratiney H, Van Reeth E. Optimal Control‐Based Generic Framework for Radiofrequency Pulse Design in MRI. NMR in Biomedicine. 2026;39(6). doi:10.1002/nbm.70307

BibTeX
@article{Molina2026,
  author = {Molina, Emilio and Ratiney, Hélène and Van Reeth, Eric},
  title = {Optimal Control‐Based Generic Framework for Radiofrequency Pulse Design in MRI},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {6},
  doi = {10.1002/nbm.70307}
}
Kostenlos starten →