Multi‐Shot Multi‐Echo xSPEN Technique for Portable Low‐Field MRI Systems

Yueqi Qiu, Philip K Lee, Ke Dai, Suen Chen, Shiwei Yang, Changyue Wang, Haoran Bai, Zhaozhao Dang, Zhiyong Zhang

NMR in Biomedicine · 2026-06 · 39 (6)

DOI: 10.1002/nbm.70294 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 20.04.2026. Verfasst von Yueqi Qiu und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Key R&D Program of China, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In compact portable low‐field MRI systems, imaging suffers from severe distortions due to significant field inhomogeneity and gradient nonlinearity. The purpose of this work was to develop and evaluate a Multi‐Shot Multi‐Echo cross‐term Spatiotemporal Encoding (MS‐ME xSPEN) sequence for highly compact, portable low‐field MRI systems. This method aims to improve imaging performance while preserving the robustness of xSPEN to severe field inhomogeneities. The MS‐ME xSPEN sequence was implemented using two image‐domain multi‐shot sampling techniques: segmented and interleaved. For subsequent evaluations, the segmented MS‐ME xSPEN approach was selected and compared with conventional single‐shot xSPEN. All experiments were performed on a 110‐mT portable MRI system equipped with three gradient axes. A constant gradient environment was emulated by continuously activating a single gradient axis throughout the sequence. Imaging was performed on phantoms and in the human brain. MS‐ME xSPEN exhibited superior resilience to in‐plane distortions from field inhomogeneities and achieved higher SNR compared with the standard xSPEN. MS‐ME xSPEN also enabled a wider range of T2‐weighted contrasts. MS‐ME xSPEN is well suited for compact portable MRI systems, offering improved SNR, flexible contrast, and robustness to field inhomogeneity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingHumansPhantoms, ImagingBrainAlgorithmsSignal-To-Noise RatioSignal Processing, Computer-AssistedReproducibility of Results

Stichwörter der Autor:innen

cross‐term SPENecho‐planar imagingportable low‐field MRIspatiotemporal encoding

Autor:innen und Institutionen

  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
  • National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai, People's Republic of China.
  • Point Imaging Co. Ltd., Shanghai, People's Republic of China.

Förderung

  • National Key R&D Program of China
  • National Key Research and Development Program of China

Zitieren

APA

Qiu, Y., Lee, P. K., Dai, K., Chen, S., Yang, S., Wang, C., Bai, H., Dang, Z., & Zhang, Z. (2026). Multi‐Shot Multi‐Echo xSPEN Technique for Portable Low‐Field MRI Systems. NMR in Biomedicine, 39(6). https://doi.org/10.1002/nbm.70294

Vancouver

Qiu Y, Lee PK, Dai K, Chen S, Yang S, Wang C, et al. Multi‐Shot Multi‐Echo xSPEN Technique for Portable Low‐Field MRI Systems. NMR in Biomedicine. 2026;39(6). doi:10.1002/nbm.70294

BibTeX
@article{Qiu2026,
  author = {Qiu, Yueqi and Lee, Philip K and Dai, Ke and Chen, Suen and Yang, Shiwei and Wang, Changyue and Bai, Haoran and Dang, Zhaozhao and Zhang, Zhiyong},
  title = {Multi‐Shot Multi‐Echo xSPEN Technique for Portable Low‐Field MRI Systems},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {6},
  doi = {10.1002/nbm.70294}
}
Kostenlos starten →