Transceiver 16‐Channel Coaxial‐End Dipole Array for Combined Head and C‐Spine MRI at 9.4 T
NMR in Biomedicine · 2026-03 · 39 (3)
DOI: 10.1002/nbm.70228 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 26.01.2026. Verfasst von G A Solomakha und 11 weiteren Autor:innen. Beteiligte Einrichtung: High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Head, Brain, Cervical Vertebrae. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 91 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DFG-ANR project NeuroBOOST, ERC Advanced Grant, BMBF Project.
Abstract (Originalsprache)
This work aims to design a double‐row transceiver array consisting of 16 folded‐end coaxial‐end dipoles for combined C‐spine and brain imaging. The curved coaxial‐end dipole elements were aligned on a tight‐fitting, ergonomically shaped conformal holder optimized for subject comfort. Transmit efficiency, B 1 + field homogeneity, and tissue‐specific absorption rate (SAR) were numerically evaluated using electromagnetic simulations and optimized with respect to several configurations of the array geometry. After identifying the optimal array configuration, the array was built and tested on a bench and in the MRI scanner, using anatomical imaging and transmit field mapping on a phantom and healthy volunteers. The designed array provided RF excitation over the entire brain and cervical spinal cord down to the C7 region, covering a field of view of more than 365 mm in head‐foot direction. Measured in a region covering the cerebrum, cerebellum, brainstem, and C‐spine, it achieved B 1 + field homogeneity of ~31% (coefficient of variation), mean transmit efficiency of ~0.38 μT/√W, and SAR efficiency of 0.65 μT/√W/kg when driven in the circularly polarized mode. The acquired anatomical MR images confirmed that the constructed array provided coverage of the brain and C‐spine.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria.
- Erwin L. Hahn Institute for MRI, University Duisburg-Essen, Essen, Germany.
- High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany.
- Electronical Workshop, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany.
ORCID-Profile: G A Solomakha, F Glang, M W May, S Mueller, A Aghaeifar, D Bosch, O Kraff, K Scheffler, N I Avdievich
Förderung
- DFG-ANR project NeuroBOOST
- ERC Advanced Grant
- BMBF Project
Zitieren
APA
Solomakha, G. A., Glang, F., May, M. W., Mueller, S., Walzog, J., Aghaeifar, A., Bosch, D., Bause, J., Kraff, O., Scheffler, K., Quick, H. H., & Avdievich, N. I. (2026). Transceiver 16‐Channel Coaxial‐End Dipole Array for Combined Head and C‐Spine MRI at 9.4 T. NMR in Biomedicine, 39(3). https://doi.org/10.1002/nbm.70228
Vancouver
Solomakha GA, Glang F, May MW, Mueller S, Walzog J, Aghaeifar A, et al. Transceiver 16‐Channel Coaxial‐End Dipole Array for Combined Head and C‐Spine MRI at 9.4 T. NMR in Biomedicine. 2026;39(3). doi:10.1002/nbm.70228
BibTeX
@article{Solomakha2026,
author = {Solomakha, G A and Glang, F and May, M W and Mueller, S and Walzog, J and Aghaeifar, A and Bosch, D and Bause, J and Kraff, O and Scheffler, K and Quick, H H and Avdievich, N I},
title = {Transceiver 16‐Channel Coaxial‐End Dipole Array for Combined Head and C‐Spine MRI at 9.4 T},
journal = {NMR in Biomedicine},
year = {2026},
volume = {39},
number = {3},
doi = {10.1002/nbm.70228}
}
EUVIMED