EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of Low‐Rank Denoising Methods for Dynamic Deuterium MRSI at 7 T

Anna Duguid, Fabian Niess iD, Wolfgang Bogner, Lukas Hingerl, Viola Bader iD, Sabina Frese, Aaron Osburg, Bernard Lanz iD, Brayan Alves, Cristina Cudalbu, Simon Daniel Robinson, Korbinian Eckstein und 1 weitere

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.70125 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Anna Duguid und 12 weiteren Autor:innen. Beteiligte Einrichtung: High Field MR Center, Department for Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Signal-To-Noise Ratio, Deuterium, Magnetic Resonance Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Science Fund, Swiss National Science Foundation, Christian Doppler Forschungsgesellschaft (BIOMAK).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dynamic deuterium ( 2 H)‐MRSI enables mapping of metabolic fluxes in vivo, but its sensitivity is hampered by the low 2 H gyromagnetic ratio and 2 H‐labelled metabolite concentrations. Low‐rank denoising can enhance MRSI sensitivity by separating signal from noise. Several methods have been proposed, but the optimal approach for dynamic 2 H‐MRSI remains unclear. This work compares six low‐rank denoising methods for dynamic 2 H‐MRSI: four variations of spatiospectral partial separability (PS)—Global PS, Local PS, Stacked PS and SPectral and temporal INtegration for SVD (SPIN‐SVD)—as well as global–local higher order singular value decomposition (GL‐HOSVD) and tensor Marchenko–Pastur principal component analysis (tMPPCA). Performance was evaluated using realistic 2 H‐MRSI brain simulations across a range of noise and B 0 inhomogeneity levels, including a lesion model featuring focal metabolic alteration, and in vivo data. For simulations at the in vivo SNR and B 0 level, the concentration root‐mean‐square errors (RMSE) of the fitted metabolite maps against gold standard maps were reduced by 29.3%, 24.4%, 20.2%, 33.4%, 23.5% and 21.9% following denoising with Global PS, Local PS, Stacked PS, SPIN‐SVD, GL‐HOSVD and tMPPCA, respectively. Across all simulated noise levels and all but the highest B 0 inhomogeneity level, SPIN‐SVD achieved the lowest concentration RMSE and best preserved spatial distributions of 2 H‐labelled water (HDO) and lactate (Lac), including lesion‐associated changes. While Global PS and Stacked PS reduced noise variance, they failed to preserve signal variations in simulated and in vivo data. SPIN‐SVD, GL‐HOSVD and tMPPCA reduced noise in vivo while maintaining spatial and temporal metabolite variations. GL‐HOSVD and tMPPCA performed similarly, with tMPPCA preferred for its computational efficiency. Both SPIN‐SVD and tMPPCA are suitable for denoising dynamic 2 H‐MRSI, with SPIN‐SVD preferable for clinical applications owing to its simple implementation and superior preservation of local metabolic alterations, and tMPPCA better suited for absolute quantification of very low SNR metabolites.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal-To-Noise RatioDeuteriumMagnetic Resonance ImagingHumansMagnetic Resonance SpectroscopyBrainPrincipal Component AnalysisAlgorithmsComputer Simulation

Stichwörter der Autor:innen

3D MRSIMRSdenoisingdeuteriumlow‐rankwhole‐brain metabolite mapping

Substanzen

Deuterium

Autor:innen und Institutionen

  • High Field MR Center, Department for Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK), Department for Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • CIBM Center for Biomedical Imaging, Lausanne, Switzerland.
  • Animal Imaging and Technology, EPFL, Lausanne, Switzerland.

ORCID-Profile: Fabian Niess, Viola Bader, Bernard Lanz

Förderung

  • Austrian Science Fund
  • Swiss National Science Foundation
  • Christian Doppler Forschungsgesellschaft (BIOMAK)
  • European Union
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
  • European Commission

Zitieren

APA

Duguid, A., Niess, F., Bogner, W., Hingerl, L., Bader, V., Frese, S., Osburg, A., Lanz, B., Alves, B., Cudalbu, C., Robinson, S. D., Eckstein, K., & Strasser, B. (2025). Comparison of Low‐Rank Denoising Methods for Dynamic Deuterium MRSI at 7 T. NMR in Biomedicine. https://doi.org/10.1002/nbm.70125

Vancouver

Duguid A, Niess F, Bogner W, Hingerl L, Bader V, Frese S, et al. Comparison of Low‐Rank Denoising Methods for Dynamic Deuterium MRSI at 7 T. NMR in Biomedicine. 2025. doi:10.1002/nbm.70125

BibTeX
@article{Duguid2025,
  author = {Duguid, Anna and Niess, Fabian and Bogner, Wolfgang and Hingerl, Lukas and Bader, Viola and Frese, Sabina and Osburg, Aaron and Lanz, Bernard and Alves, Brayan and Cudalbu, Cristina and Robinson, Simon Daniel and Eckstein, Korbinian and Strasser, Bernhard},
  title = {Comparison of Low‐Rank Denoising Methods for Dynamic Deuterium MRSI at 7 T},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.70125}
}
Kostenlos starten →