EUVIMEDEUVIMED entdecken
Crossref

Accelerated MR cell size imaging through parallel acquisition technique (PAT) and simultaneous multi-slice (SMS) with local principal component analysis (LPCA) enhancement

Tianxiong Wu, Jiayu Sun, Zhihao Wang, Jia Tan, Xianqing Tang, Deng Xiong, Thorsten Feiweier, Qiyong Gong, Haoyang Xing, Min Wu

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2025.110327 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Tianxiong Wu und 9 weiteren Autor:innen. Beteiligte Einrichtung: College of Physics, Sichuan University, No.24 South Section 1, 1(st) Ring Road, Chengdu, Sichuan 610045, China; Functional and Molecular Imaging Key …. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cell Size, Image Processing, Computer-Assisted, Brain Neoplasms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microstructural parameters are essential in tumor research, aiding in the understanding tumor pathogenesis, grading, and therapeutic efficacy. The imaging microstructural parameters using limited spectrally edited diffusion (IMPULSED) model is the most widely used MR cell size imaging technique, demonstrating success in measuring microstructural parameters of solid tumors in vivo. However, its clinical application is limited by the longer scan times required for both pulsed gradient spin-echo (PGSE) and multiple oscillating gradient spin-echo (OGSE) acquisitions across a range of b-values, which can be burdensome for patients and disrupt clinical workflows. In this work, we propose and evaluate an accelerating method that integrates parallel acquisition technique (PAT) and simultaneous multi-slice (SMS) with local principal component analysis (LPCA) denoising to reduce scan times while maintaining image quality in MR cell size imaging. PGSE and OGSE (25 Hz, 50 Hz) images were acquired using P2S2 (PAT2-SMS2), P2S3 (PAT2-SMS3), and P3S3 (PAT3-SMS3) configurations, incorporating LPCA denoising, and compared to standard P2 (PAT2-SMS1) in healthy volunteers and brain tumor patients at 3 T. Additionally, clinical feasibility was further assessed through qualitative and quantitative evaluations. Qualitative assessment, conducted by two radiologists using a 5-point Likert scale, and quantitative analysis, including noise estimation, apparent diffusion coefficient (ADC) calculation, and estimation of microstructural parameters-cell diameter (Dmean), intracellular volume fraction (Vin), and extracellular diffusivity (Dex), were performed. Overall, the integration of PAT and SMS techniques reduces acquisition time by approximately 60 % compared to standard P2 acceleration, while maintaining comparable image quality and structural fidelity with LPCA denoising.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingCell SizeImage Processing, Computer-AssistedBrain NeoplasmsImage EnhancementHumansPrincipal Component AnalysisAlgorithmsBrainSignal-To-Noise RatioMaleFemale

Stichwörter der Autor:innen

Diffusion-weighted imagingIMPULSEDMRIMicrostructural parametersOscillating gradientParallel imagingSimultaneous multi-slice

Autor:innen und Institutionen

  • College of Physics, Sichuan University, No.24 South Section 1, 1(st) Ring Road, Chengdu, Sichuan 610045, China; Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital of Sichuan Univers…
  • Department of Radiology, West China Hospital of Sichuan University, No.37 Guo Xue Alley, Chengdu, Sichuan 610041, China. Electronic address: sjy080512@163.com.
  • Department of Neurosurgery, West China Hospital of Sichuan University, No.37 Guo Xue Alley, Chengdu, Sichuan 610041, China. Electronic address: wangzhihaotnl@foxmail.com.
  • Department of Radiology, West China Hospital of Sichuan University, No.37 Guo Xue Alley, Chengdu, Sichuan 610041, China. Electronic address: tanjia8600@wchscu.cn.
  • West China Xiamen Hospital of Sichuan University, No.699 Jinyuan West Road, Xiamen, Fujian 361022, China. Electronic address: t1413194910@gmail.com.
  • Computer Science Department/Mechanical Engineering Department, Stevens Institute of Technology, 1 Castle Point Terrace, Hoboken, NJ 07030, USA. Electronic address: dxiong@stevens.edu.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Wu, T., Sun, J., Wang, Z., Tan, J., Tang, X., Xiong, D., Feiweier, T., Gong, Q., Xing, H., & Wu, M. (2025). Accelerated MR cell size imaging through parallel acquisition technique (PAT) and simultaneous multi-slice (SMS) with local principal component analysis (LPCA) enhancement. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110327

Vancouver

Wu T, Sun J, Wang Z, Tan J, Tang X, Xiong D, et al. Accelerated MR cell size imaging through parallel acquisition technique (PAT) and simultaneous multi-slice (SMS) with local principal component analysis (LPCA) enhancement. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110327

BibTeX
@article{Wu2025,
  author = {Wu, Tianxiong and Sun, Jiayu and Wang, Zhihao and Tan, Jia and Tang, Xianqing and Xiong, Deng and Feiweier, Thorsten and Gong, Qiyong and Xing, Haoyang and Wu, Min},
  title = {Accelerated MR cell size imaging through parallel acquisition technique (PAT) and simultaneous multi-slice (SMS) with local principal component analysis (LPCA) enhancement},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2025.110327}
}
Kostenlos starten →