In Vivo Quantitative T 1 and T 2 Mapping of Human Breast Tissues Using a Custom‐Built 50‐mT MRI Prototype
NMR in Biomedicine · 2025
DOI: 10.1002/nbm.70081 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Zhengxiu Wu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Jiangsu Key Laboratory for Design and Manufacturing of Precision Medicine Equipment, Southeast University, Nanjing, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Breast. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Postgraduate Research and Practice Innovation Program of Jiangsu Province.
Abstract (Originalsprache)
The renewed interest in ultra‐low‐field MRI (< 0.1 T), with its advantages of cost‐effectiveness and portability, is expected to drive a paradigm shift from traditional MRI scanners to point‐of‐care imaging systems. Here, we characterized the in vivo T 1 and T 2 relaxation times of healthy breast tissues using quantitative MRI at 50 mT to advance the development of ultra‐low‐field breast MRI methodologies. First, the developed in vivo quantitative mapping protocols were tested and validated using CuSO 4 ‐doped water phantom experiments on the custom‐built 50‐mT MRI prototype. Then, in vivo quantitative T 1 and T 2 mapping of human breast tissues was measured in healthy female subjects. The T 1 and T 2 values for fat tissue, fibrous tissue, and glandular tissue components were determined using an automatic segmentation method based on the relaxation times. The mean T 1 times were 121.21 ± 14.57, 182.26 ± 20.96, and 238.32 ± 10.71 ms for fat tissue, fibrous tissue, and glandular tissue, respectively. While the mean T 2 times were 111.36 ± 14.28 and 69.44 ± 15.26 ms for fat tissue and fibroglandular tissue, respectively. For healthy breast tissues, the significantly shorter T 1 times at 50 mT are favorable for improving the imaging speed. T 2 times are similar to those seen at conventional clinical field strengths. Additionally, the relatively small difference in T 2 times between fibrous tissue and glandular tissue made it difficult to segment these two tissues independently. This work can provide a valuable reference for future breast tissues diagnostic imaging in ultra‐low‐field MRI scenarios, thereby promoting the wider adoption of portable breast MRI in routine breast disease screening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Jiangsu Key Laboratory for Design and Manufacturing of Precision Medicine Equipment, Southeast University, Nanjing, China.
- School of Mechanical Engineering, Southeast University, Nanjing, China.
- National Platform for Medical Engineering Education Integration, Southeast University, Nanjing, China.
- NingBo ChuanShanjia Electrical and Mechanical Co., Ltd, Ningbo, China.
ORCID-Profile: Rongsheng Lu
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
- Postgraduate Research and Practice Innovation Program of Jiangsu Province
- Key Research and Development Program of Jiangsu, China
- Science and Technology Major Project of Nanjing, China
- National Basic Research Program of China
Zitieren
APA
Wu, Z., Guo, J., Tang, Z., Hu, X., Jiang, X., Ni, Z., & Lu, R. (2025). In Vivo Quantitative T 1 and T 2 Mapping of Human Breast Tissues Using a Custom‐Built 50‐mT MRI Prototype. NMR in Biomedicine. https://doi.org/10.1002/nbm.70081
Vancouver
Wu Z, Guo J, Tang Z, Hu X, Jiang X, Ni Z, et al. In Vivo Quantitative T 1 and T 2 Mapping of Human Breast Tissues Using a Custom‐Built 50‐mT MRI Prototype. NMR in Biomedicine. 2025. doi:10.1002/nbm.70081
BibTeX
@article{Wu2025,
author = {Wu, Zhengxiu and Guo, Jiangqian and Tang, Zicheng and Hu, Xiaokai and Jiang, Xiaowen and Ni, Zhonghua and Lu, Rongsheng},
title = {In Vivo Quantitative T 1 and T 2 Mapping of Human Breast Tissues Using a Custom‐Built 50‐mT MRI Prototype},
journal = {NMR in Biomedicine},
year = {2025},
doi = {10.1002/nbm.70081}
}
EUVIMED