Development of a Double Tuned 2 H/ 31 P Whole‐Body Birdcage Transmit Coil for 2 H and 31 P MR Applications From Head to Toe at 7 T
NMR in Biomedicine · 2025-03 · 38 (3)
DOI: 10.1002/nbm.5325 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 31.01.2025. Verfasst von Ayhan Gursan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Phosphorus Isotopes, Magnetic Resonance Imaging, Deuterium, Whole Body Imaging. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NWO TTW, EU IEC transition grant (MITI), EU.
Abstract (Originalsprache)
Deuterium ( 2 H) and phosphorus ( 31 P) magnetic resonance spectroscopy (MRS) are complementary methods for evaluating tissue metabolism noninvasively in vivo. Combined 2 H and 31 P MRS would therefore be of interest for various applications, from cancer to diabetes. Loop coils are commonly used in X‐nuclei studies in the human body for both transmit and receive. However, loop coils suffer from limited penetration depth and inhomogeneous B 1 + field. The purpose of this work is to develop a double tuned 2 H/ 31 P whole‐body birdcage transmit coil for 7 T for 2 H and 31 P MRS imaging (MRSI) with homogeneous excitation over a large field‐of‐view. The performance of the 2 H/ 31 P birdcage coil was assessed on B 1 + fields over a body‐sized phantom at 2 H and 31 P frequencies using an 8‐channel 2 H/ 31 P receive array. Using two elements of the 2 H/ 31 P receive array, natural abundance 2 H and 31 P 3D MRSI data at rest were acquired consecutively in the brain and lower leg muscles. Additionally, 2 H and 31 P 3D MRSI data were acquired from one volunteer 90 min after [6,6′‐ 2 H 2 ]‐glucose intake, using 8‐channel 2 H/ 31 P receive array around the abdomen. The B 1 + variation of the whole‐body birdcage coil over the phantom was 12.1% for 2 H and 19.2% for 31 P. High‐quality 2 H and 31 P 3D MRSI data were acquired from the brain and the lower leg. Whole liver coverage was achieved in both 2 H and 31 P 3D MRSI data. The developed 2 H/ 31 P whole‐body birdcage transmit coil allows simultaneous 3D mapping of glucose and energy metabolism and membrane turnover throughout the human body.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands.
- Departments of Human Biology and Imaging, NUTRIM Institute of Nutrition and Translational Research in Metabolism, Maastricht University Medical Centre+, Maastricht, The Netherlands.
ORCID-Profile: Ayhan Gursan, Busra Kahraman-Agir, Martijn Froeling, Jeanine J Prompers
Förderung
- NWO TTW
- EU IEC transition grant (MITI)
- EU
- European Commission
Zitieren
APA
Gursan, A., Kahraman-Agir, B., Gosselink, M., Welting, D., Froeling, M., Hoogduin, H., Wiegers, E. C., Prompers, J. J., & Klomp, D. W. J. (2025). Development of a Double Tuned 2 H/ 31 P Whole‐Body Birdcage Transmit Coil for 2 H and 31 P MR Applications From Head to Toe at 7 T. NMR in Biomedicine, 38(3). https://doi.org/10.1002/nbm.5325
Vancouver
Gursan A, Kahraman-Agir B, Gosselink M, Welting D, Froeling M, Hoogduin H, et al. Development of a Double Tuned 2 H/ 31 P Whole‐Body Birdcage Transmit Coil for 2 H and 31 P MR Applications From Head to Toe at 7 T. NMR in Biomedicine. 2025;38(3). doi:10.1002/nbm.5325
BibTeX
@article{Gursan2025,
author = {Gursan, Ayhan and Kahraman-Agir, Busra and Gosselink, Mark and Welting, Dimitri and Froeling, Martijn and Hoogduin, Hans and Wiegers, Evita C and Prompers, Jeanine J and Klomp, Dennis W J},
title = {Development of a Double Tuned 2 H/ 31 P Whole‐Body Birdcage Transmit Coil for 2 H and 31 P MR Applications From Head to Toe at 7 T},
journal = {NMR in Biomedicine},
year = {2025},
volume = {38},
number = {3},
doi = {10.1002/nbm.5325}
}
EUVIMED