EUVIMEDEUVIMED entdecken
Crossref

Improvements in precision and accuracy of complex‐ relative to real‐domain linear combination model spectral fitting not necessarily recovered by zero filling

Leonardo Campos, Kelley M Swanberg, Martin Gajdošík iD, Karl Landheer iD, Christoph Juchem

NMR in Biomedicine · 2024

DOI: 10.1002/nbm.5236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Leonardo Campos und 4 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering, Columbia University, New York, New York, USA. Hauptthemen laut MEDLINE: Computer Simulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Although the information obtained from in vivo proton magnetic resonance spectroscopy ( 1 H MRS) presents a complex‐valued spectrum, spectral quantification generally employs linear combination model (LCM) fitting using the real spectrum alone. There is currently no known investigation comparing fit results obtained from LCM fitting over the full complex data versus the real data and how these results might be affected by common spectral preprocessing procedure zero filling. Here, we employ linear combination modeling of simulated and measured spectral data to examine two major ideas: first, whether use of the full complex rather than real‐only data can provide improvements in quantification by linear combination modeling and, second, to what extent zero filling might influence these improvements. We examine these questions by evaluating the errors of linear combination model fits in the complex versus real domains against three classes of synthetic data: simulated Lorentzian singlets, simulated metabolite spectra excluding the baseline, and simulated metabolite spectra including measured in vivo baselines. We observed that complex fitting provides consistent improvements in fit accuracy and precision across all three data types. While zero filling obviates the accuracy and precision benefit of complex fitting for Lorentzian singlets and metabolite spectra lacking baselines, it does not necessarily do so for complex spectra including measured in vivo baselines. Overall, performing linear combination modeling in the complex domain can improve metabolite quantification accuracy relative to real fits alone. While this benefit can be similarly achieved via zero filling for some spectra with flat baselines, this is not invariably the case for all baseline types exhibited by measured in vivo data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer SimulationLinear ModelsHumansAlgorithmsProton Magnetic Resonance SpectroscopyMagnetic Resonance SpectroscopyReproducibility of Results

Stichwörter der Autor:innen

applied complex analysisbrainlinear combination modelingsingle‐voxel in vivo proton magnetic resonance spectroscopyspectral baselinesspectral quantificationzero filling

Autor:innen und Institutionen

  • Biomedical Engineering, Columbia University, New York, New York, USA.
  • Radiology, Columbia University, New York, New York, USA.

ORCID-Profile: Martin Gajdošík, Karl Landheer

Zitieren

APA

Campos, L., Swanberg, K. M., Gajdošík, M., Landheer, K., & Juchem, C. (2024). Improvements in precision and accuracy of complex‐ relative to real‐domain linear combination model spectral fitting not necessarily recovered by zero filling. NMR in Biomedicine. https://doi.org/10.1002/nbm.5236

Vancouver

Campos L, Swanberg KM, Gajdošík M, Landheer K, Juchem C. Improvements in precision and accuracy of complex‐ relative to real‐domain linear combination model spectral fitting not necessarily recovered by zero filling. NMR in Biomedicine. 2024. doi:10.1002/nbm.5236

BibTeX
@article{Campos2024,
  author = {Campos, Leonardo and Swanberg, Kelley M and Gajdošík, Martin and Landheer, Karl and Juchem, Christoph},
  title = {Improvements in precision and accuracy of complex‐ relative to real‐domain linear combination model spectral fitting not necessarily recovered by zero filling},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5236}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche