Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Christopher W Davies-Jenkins und 5 weiteren Autor:innen. Beteiligte Einrichtung: The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Algorithms, Brain, Brain Neoplasms, Proton Magnetic Resonance Spectroscopy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIA NIH HHS, NIBIB NIH HHS, NIH HHS.
Abstract (Originalsprache)
Purpose
Metabolite amplitude estimates derived from linear combination modeling of MR spectra depend on the precise list of constituent metabolite basis functions used (the “basis set”). The absence of clear consensus on the “ideal” composition or objective criteria to determine the suitability of a particular basis set contributes to the poor reproducibility of MRS. In this proof‐of‐concept study, we demonstrate a novel, data‐driven approach for deciding the basis‐set composition using Akaike information criteria (AIC).
Methods
We have developed an algorithm that iteratively adds metabolites to the basis set using iterative modeling, informed by AIC scores. We investigated two quantitative “stopping conditions,” referred to as max‐AIC and zero‐amplitude, and whether to optimize the selection of basis set on a per‐spectrum basis or at the group level. The algorithm was tested using two groups of synthetic in vivo‐like spectra representing healthy brain and tumor spectra, respectively, and the derived basis sets (and metabolite amplitude estimates) were compared to the ground truth.
Results
All derived basis sets correctly identified high‐concentration metabolites and provided reasonable fits of the spectra. At the single‐spectrum level, the two stopping conditions derived the underlying basis set with 84% to 88% accuracy. When optimizing across a group, basis set determination accuracy improved to 89% to 92%.
Conclusion
Data‐driven determination of the basis set composition is feasible. With refinement, this approach could provide a valuable data‐driven way to derive or refine basis sets, reducing the operator bias of MRS analyses, enhancing the objectivity of quantitative analyses, and increasing the clinical viability of MRS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Institute of Neuroradiology, University Hospital Frankfurt, Goethe University, Frankfurt/Main, Germany.
- University Cancer Center Frankfurt (UCT), Frankfurt/Main, Germany.
- Frankfurt Cancer Institute (FCI), Frankfurt/Main, Germany.
ORCID-Profile: Christopher W Davies-Jenkins, Helge J Zöllner, Dunja Simicic, Seyma Alcicek, Georg Oeltzschner
Förderung
- NIA NIH HHS
- NIBIB NIH HHS
- NIH HHS
- Mildred Scheel Career Center
- Deutsche Krebshilfe
- National Institutes of Health
Zitieren
APA
Davies-Jenkins, C. W., Zöllner, H. J., Simicic, D., Alcicek, S., Edden, R. A. E., & Oeltzschner, G. (2026). A data‐driven algorithm to determine 1 H ‐ MRS basis set composition. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70030
Vancouver
Davies-Jenkins CW, Zöllner HJ, Simicic D, Alcicek S, Edden RAE, Oeltzschner G. A data‐driven algorithm to determine 1 H ‐ MRS basis set composition. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70030
BibTeX
@article{DaviesJenkins2026,
author = {Davies-Jenkins, Christopher W and Zöllner, Helge J and Simicic, Dunja and Alcicek, Seyma and Edden, Richard A E and Oeltzschner, Georg},
title = {A data‐driven algorithm to determine 1 H ‐ MRS basis set composition},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70030}
}
EUVIMED