EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Arterial input function estimation compensating for inflow and partial voluming in dynamic contrast‐enhanced MRI

Chih-Hsien Tseng iD, Martijn A Nagtegaal, Matthias J P van Osch iD, Jaap Jaspers, Alejandra Mendez Romero, Piotr Wielopolski, Marion Smits, Frans M Vos

NMR in Biomedicine · 2024

DOI: 10.1002/nbm.5225 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Chih-Hsien Tseng und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands. Hauptthemen laut MEDLINE: Contrast Media, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Medical Delta Cancer Diagnostics 3.0, HollandPTC-Varian Consortium.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Both inflow and the partial volume effect (PVE) are sources of error when measuring the arterial input function (AIF) in dynamic contrast‐enhanced (DCE) MRI. This is relevant, as errors in the AIF can propagate into pharmacokinetic parameter estimations from the DCE data. A method was introduced for flow correction by estimating and compensating the number of the perceived pulse of spins during inflow. We hypothesized that the PVE has an impact on concentration–time curves similar to inflow. Therefore, we aimed to study the efficiency of this method to compensate for both effects simultaneously. We first simulated an AIF with different levels of inflow and PVE contamination. The peak, full width at half‐maximum (FWHM), and area under curve (AUC) of the reconstructed AIFs were compared with the true (simulated) AIF. In clinical data, the PVE was included in AIFs artificially by averaging the signal in voxels surrounding a manually selected point in an artery. Subsequently, the artificial partial volume AIFs were corrected and compared with the AIF from the selected point. Additionally, corrected AIFs from the internal carotid artery (ICA), the middle cerebral artery (MCA), and the venous output function (VOF) estimated from the superior sagittal sinus (SSS) were compared. As such, we aimed to investigate the effectiveness of the correction method with different levels of inflow and PVE in clinical data. The simulation data demonstrated that the corrected AIFs had only marginal bias in peak value, FWHM, and AUC. Also, the algorithm yielded highly correlated reconstructed curves over increasingly larger neighbourhoods surrounding selected arterial points in clinical data. Furthermore, AIFs measured from the ICA and MCA produced similar peak height and FWHM, whereas a significantly larger peak and lower FWHM was found compared with the VOF. Our findings indicate that the proposed method has high potential to compensate for PVE and inflow simultaneously. The corrected AIFs could thereby provide a stable input source for DCE analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaMagnetic Resonance ImagingHumansArteriesComputer SimulationMaleFemaleAlgorithmsMiddle AgedAdult

Stichwörter der Autor:innen

DCE MRIarterial input functioninflow effectpartial volume effect

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands.
  • Medical Delta, Delft, the Netherlands.
  • HollandPTC Consortium-Erasmus MC, Rotterdam, Holland Proton Therapy Center, Delft, Leiden University Medical Center, Leiden and Delft University of Technology, Delft, the Netherlands.
  • C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands.
  • Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.
  • Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.

ORCID-Profile: Chih-Hsien Tseng, Matthias J P van Osch

Förderung

  • Medical Delta Cancer Diagnostics 3.0
  • HollandPTC-Varian Consortium

Zitieren

APA

Tseng, C. H., Nagtegaal, M. A., van Osch, M. J. P., Jaspers, J., Mendez Romero, A., Wielopolski, P., Smits, M., & Vos, F. M. (2024). Arterial input function estimation compensating for inflow and partial voluming in dynamic contrast‐enhanced MRI. NMR in Biomedicine. https://doi.org/10.1002/nbm.5225

Vancouver

Tseng CH, Nagtegaal MA, van Osch MJP, Jaspers J, Mendez Romero A, Wielopolski P, et al. Arterial input function estimation compensating for inflow and partial voluming in dynamic contrast‐enhanced MRI. NMR in Biomedicine. 2024. doi:10.1002/nbm.5225

BibTeX
@article{Tseng2024,
  author = {Tseng, Chih-Hsien and Nagtegaal, Martijn A and van Osch, Matthias J P and Jaspers, Jaap and Mendez Romero, Alejandra and Wielopolski, Piotr and Smits, Marion and Vos, Frans M},
  title = {Arterial input function estimation compensating for inflow and partial voluming in dynamic contrast‐enhanced MRI},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5225}
}
Kostenlos starten →