Exploring the need for a preload on the estimation of permeability, vessel radius, and relative cerebral blood volume in MR vascular fingerprinting–based dynamic susceptibility contrast perfusion imaging
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30383 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Daniëlle van Dorth und 7 weiteren Autor:innen. Beteiligte Einrichtung: C. J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands. Hauptthemen laut MEDLINE: Contrast Media, Brain Neoplasms, Cerebral Blood Volume, Magnetic Resonance Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Toegepaste en Technische Wetenschappen, NWO.
Abstract (Originalsprache)
Purpose
Dynamic susceptibility contrast (DSC) MRI is commonly part of the clinical brain tumor imaging protocol. Usually, a preload of contrast agent is administered to minimize contrast‐leakage T 1 effects. However, recent studies have indicated that with adaptation of scan parameters (in particular, low flip angle), a preload is not required. For advanced approaches, like MR vascular fingerprinting (MRVF), which is based on combining gradient‐echo and spin‐echo readouts, excitation flip angles cannot easily be reduced, but postprocessing might alleviate leakage effects. In this study, the aim was to verify whether DSC‐MRVF can be performed without preload.
Methods
A previously established simulation model was used to create a dictionary of DSC‐MRVF signals resulting from a double‐bolus injection with varying input values for permeability, vessel radius, and relative cerebral blood volume (rCBV). A sensitivity analysis based on a Cramer Rao Lower Bound approach was performed, from which the logarithmic ratio of standard deviations for parameter estimation was derived. A ratio above zero corresponded with a better determination without preload. Two brain tumor patients were included for validation.
Results
The results show that the standard deviation for determining permeability was lower without preload, whereas for determining rCBV, the opposite result was found. For vessel radius, the standard deviation was similar with and without preload. The in vivo data reasonably agreed with the simulation results.
Conclusion
This work has shown the potential of DSC‐MRVF with a single bolus injection for determining vessel radius and permeability, although for rCBV, a preload is still advisable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- C. J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands.
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, University Medical Center Rotterdam, Rotterdam, Netherlands.
- Medical Delta, Delft, Netherlands.
- Brain Tumor Center, Erasmus Medical Center Cancer Institute, Rotterdam, Netherlands.
ORCID-Profile: Daniëlle van Dorth, Krishnapriya Venugopal, Karen N van der Werff, Marion Smits, Esther A H Warnert, Juan A Hernandez-Tamames, Matthias J P van Osch, Dirk H J Poot
Förderung
- Toegepaste en Technische Wetenschappen, NWO
Zitieren
APA
van Dorth, D., Venugopal, K., van der Werff, K. N., Smits, M., Warnert, E. A. H., Hernandez-Tamames, J. A., van Osch, M. J. P., & Poot, D. H. J. (2025). Exploring the need for a preload on the estimation of permeability, vessel radius, and relative cerebral blood volume in MR vascular fingerprinting–based dynamic susceptibility contrast perfusion imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30383
Vancouver
van Dorth D, Venugopal K, van der Werff KN, Smits M, Warnert EAH, Hernandez-Tamames JA, et al. Exploring the need for a preload on the estimation of permeability, vessel radius, and relative cerebral blood volume in MR vascular fingerprinting–based dynamic susceptibility contrast perfusion imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30383
BibTeX
@article{vanDorth2025,
author = {van Dorth, Daniëlle and Venugopal, Krishnapriya and van der Werff, Karen N and Smits, Marion and Warnert, Esther A H and Hernandez-Tamames, Juan A and van Osch, Matthias J P and Poot, Dirk H J},
title = {Exploring the need for a preload on the estimation of permeability, vessel radius, and relative cerebral blood volume in MR vascular fingerprinting–based dynamic susceptibility contrast perfusion imaging},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30383}
}
EUVIMED