EUVIMEDEUVIMED entdecken
Crossref

Improvement of MRS at ultra‐high field using a wireless RF array

Andrew Frankini, Gaurav Verma, Alan C Seifert iD, Bradley N Delman, Varun Subramaniam, Priti Balchandani, Akbar Alipour

NMR in Biomedicine · 2024

DOI: 10.1002/nbm.5224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Andrew Frankini und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic, Molecular and Interventional Radiology, BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at M…. Hauptthemen laut MEDLINE: Radio Waves, Wireless Technology, Magnetic Resonance Imaging. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: NIH HHS, Korea National Institute of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We aim to assess a straightforward technique to enhance spectral quality in the brain, particularly in the cerebellum, during 7 T MRI scans. This is achieved through a wireless RF array insert designed to mitigate signal dropouts caused by the limited transmit field efficiency in the inferior part of the brain. We recently developed a wireless RF array to improve MRI and 1 H‐MRS at 7 T by augmenting signal via inductive coupling between the wireless RF array and the MRI coil. In vivo experiments on a Siemens 7 T whole‐body human scanner with a Nova 1Tx/32Rx head coil quantified the impact of the dorsal cervical array in improving signal in the posterior fossa, including the cerebellum, where the transmit efficiency of the coil is inherently low. The 1 H‐MRS experimental protocol consisted of paired acquisition of data sets, both with and without the RF array, using the semi‐LASER and SASSI sequences. The overall results indicate that the localized 1 H‐MRS is improved significantly in the presence of the array. Comparison of in vivo 1 H‐MRS plots in the presence versus absence of the array demonstrated an average SNR enhancement of a factor of 2.2. LCModel analysis reported reduced Cramér–Rao lower bounds, indicating more confident fits. This wireless RF array can significantly increase detection sensitivity. It may reduce the RF transmission power and data acquisition time for 1 H‐MRS and MRI applications, specifically at 7 T, where 1 H‐MRS requires a high‐power RF pulse. The array could provide a cost‐effective and efficient solution to improve detection sensitivity for human 1 H‐MRS and MRI in the regions with lower transmit efficiency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radio WavesWireless TechnologyMagnetic Resonance ImagingHumansSignal-To-Noise RatioMagnetic Resonance SpectroscopyMaleBrainAdultFemaleProton Magnetic Resonance Spectroscopy

Stichwörter der Autor:innen

B 1 + inhomogeneityMRSRF resonator arrayultra‐high field

Autor:innen und Institutionen

  • Department of Diagnostic, Molecular and Interventional Radiology, BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, New York, USA.

ORCID-Profile: Alan C Seifert

Förderung

  • NIH HHS
  • Korea National Institute of Health

Zitieren

APA

Frankini, A., Verma, G., Seifert, A. C., Delman, B. N., Subramaniam, V., Balchandani, P., & Alipour, A. (2024). Improvement of MRS at ultra‐high field using a wireless RF array. NMR in Biomedicine. https://doi.org/10.1002/nbm.5224

Vancouver

Frankini A, Verma G, Seifert AC, Delman BN, Subramaniam V, Balchandani P, et al. Improvement of MRS at ultra‐high field using a wireless RF array. NMR in Biomedicine. 2024. doi:10.1002/nbm.5224

BibTeX
@article{Frankini2024,
  author = {Frankini, Andrew and Verma, Gaurav and Seifert, Alan C and Delman, Bradley N and Subramaniam, Varun and Balchandani, Priti and Alipour, Akbar},
  title = {Improvement of MRS at ultra‐high field using a wireless RF array},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5224}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche