Corrections for Rabi oscillations in cardiac chemical exchange saturation transfer MRI under the influence of very short preparation pulses
NMR in Biomedicine · 2024
DOI: 10.1002/nbm.5081 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Daniel Schache und 4 weiteren Autor:innen. Beteiligte Einrichtung: Translational Research Imaging Center, Clinic of Radiology, University of Münster, Münster, Germany. Hauptthemen laut MEDLINE: Algorithms, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Very short chemical exchange saturation transfer (CEST) pulses are beneficial in cardiac continuous wave (cw) CEST MRI, especially in small animals because of their rapid heartbeat; however, they result in signal modulations caused by Rabi oscillations. Therefore, we implemented two different filter techniques, DOwnsampling by SEparation of CEST spectrum into two parts (DOSE) and time domain (TD)‐based filtering, to correct for these signal corruptions, allowing a reliable quantification of glucose‐weighted CEST (glucoCEST) MRI contrast. In our study, cw CEST measurements were performed on a 9.4‐T small animal BioSpec system using CEST pulses in the range of 10 to 200 ms. Experimental dependencies of Rabi oscillations on key MRI parameters were validated by Bloch–McConnell (BM) simulations. Filter efficiency was explored in a glucose concentration series as well as in the myocardium of healthy mice ( n = 8), and glucoCEST contrast was subsequently quantified. The experimental results showed that the impact of Rabi oscillations on CEST spectra increased with decreasing CEST pulse length, optimized B 0 homogeneity, and shorter T 2 relaxation time, in accordance with results from BM simulations. Both investigated filter techniques reduced these signal modulations significantly, with DOSE filtering preserving the amplitude and TD filtering the spectral information of CEST data more accurately. Upon filter application, a significant decrease in glucoCEST contrast in the myocardium of healthy mice was observed after glucose infusion (p TD = 0.0079, p DOSE = 0.0044). To conclude, this study offers comprehensive experimental insights into Rabi oscillations within CEST MRI data along with methodological considerations that could be further advanced into a robust and precise cardiac cw CEST protocol by integrating DOSE and TD filtering into the standard CEST analysis pipeline.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Translational Research Imaging Center, Clinic of Radiology, University of Münster, Münster, Germany.
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Bonn, Germany.
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Schache, D., Peddi, A., Nahardani, A., Faber, C., & Hoerr, V. (2024). Corrections for Rabi oscillations in cardiac chemical exchange saturation transfer MRI under the influence of very short preparation pulses. NMR in Biomedicine. https://doi.org/10.1002/nbm.5081
Vancouver
Schache D, Peddi A, Nahardani A, Faber C, Hoerr V. Corrections for Rabi oscillations in cardiac chemical exchange saturation transfer MRI under the influence of very short preparation pulses. NMR in Biomedicine. 2024. doi:10.1002/nbm.5081
BibTeX
@article{Schache2024,
author = {Schache, Daniel and Peddi, Ajay and Nahardani, Ali and Faber, Cornelius and Hoerr, Verena},
title = {Corrections for Rabi oscillations in cardiac chemical exchange saturation transfer MRI under the influence of very short preparation pulses},
journal = {NMR in Biomedicine},
year = {2024},
doi = {10.1002/nbm.5081}
}
EUVIMED