EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

Liver T1 , T2 , T2 *, and PDFF Mapping at 0. 55 T Using Rosette MRF With Optimized Sequence Design and Deep Image Reconstruction

Tom Griesler iD, Jesse Hamilton iD, Evan Cummings iD, Jacob Richardson, Andrew Whiteman, Maximilian Gram, Gastao Cruz iD, Hero Hussain, Nicole Seiberlich

Magnetic Resonance in Medicine · 2026-11-15

DOI: 10.1002/mrm.70667 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-11-15. Written by Tom Griesler and 8 co-authors. Institution: Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA. 64 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIH HHS, Siemens Healthineers, National Institutes of Health.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Purpose

Quantitative imaging on mid‐field (0.55 T) MRI systems can suffer from poor precision due to low SNR. This work presents an MRF pulse sequence optimized with Cramer‐Rao lower bound (CRLB) and combined with a multi‐echo deep image prior (DIP) reconstruction for co‐registered T1/T2/T2*/PDFF mapping in the liver at 0.55 T within a single breath‐hold.

Methods

A 20 s 2D multi‐echo rosette MRF breath‐hold acquisition was implemented on a 0.55 T wide‐bore system. The sequence design was optimized via pseudorandom search using a CRLB‐based objective for T1/T2 encoding and compared with reference designs. Data were reconstructed using (i) an iterative low‐rank (LR) reconstruction and (ii) a multi‐echo DIP jointly modeling TR‐ and echo‐domain dynamics including B0 effects. Water/fat separation preceded dictionary matching for T1/T2; curve fitting was used to calculate T2* and PDFF was derived from M0 with noise‐bias correction. The method was evaluated in numerical simulations, NIST and fat‐fraction phantom scans, and in vivo acquisitions in 10 healthy subjects. A linear mixed‐effects model was used to evaluate the effects of sequence design and reconstruction method on mapping accuracy and precision.

Results

Optimized sequences achieved lower CRLB cost than reference designs and, in simulations, CRLB cost was correlated with T1/T2 ROI variability ( R 2 = 0.76 LR; R 2 = 0.83 DIP). Phantom experiments showed agreement with reference values. In vivo, both sequence optimization and DIP reconstruction significantly reduced the standard deviation of all four parameters in liver ROIs.

Conclusion

CRLB‐guided acquisition and multi‐echo DIP reconstruction enable accurate and precise liver MRF T1/T2/T2*/PDFF mapping at 0.55 T in a single breath‐hold.

Subjects

Author keywords

MR fingerprintingdeep image priorfat quantificationliver MRIquantitative MRIsequence optimization

Authors and institutions

  • Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Biostatistics, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Internal Medicine I, University Hospital Wuerzburg, Wuerzburg, Germany.

ORCID profiles: Tom Griesler, Jesse Hamilton, Evan Cummings, Gastao Cruz

Funding

  • NIH HHS
  • Siemens Healthineers
  • National Institutes of Health

Cite

APA

Griesler, T., Hamilton, J., Cummings, E., Richardson, J., Whiteman, A., Gram, M., Cruz, G., Hussain, H., & Seiberlich, N. (2026). Liver T1 , T2 , T2 *, and PDFF Mapping at 0. 55 T Using Rosette MRF With Optimized Sequence Design and Deep Image Reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70667

Vancouver

Griesler T, Hamilton J, Cummings E, Richardson J, Whiteman A, Gram M, et al. Liver T1 , T2 , T2 *, and PDFF Mapping at 0. 55 T Using Rosette MRF With Optimized Sequence Design and Deep Image Reconstruction. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70667

BibTeX
@article{Griesler2026,
  author = {Griesler, Tom and Hamilton, Jesse and Cummings, Evan and Richardson, Jacob and Whiteman, Andrew and Gram, Maximilian and Cruz, Gastao and Hussain, Hero and Seiberlich, Nicole},
  title = {Liver T1 , T2 , T2 *, and PDFF Mapping at 0. 55 T Using Rosette MRF With Optimized Sequence Design and Deep Image Reconstruction},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70667}
}
Start for free →