Towards Faster Fetal 3D CINE Cardiac MRI Reconstruction Using Region‐Optimized Virtual Coils ( ROVir )
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 159-168
DOI: 10.1002/mrm.70590 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 22.09.2026. Verfasst von Marjolein Piek und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Cine, Fetal Heart, Prenatal Diagnosis. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Region Skåne, Skånes universitetssjukhus, Hjärt-Lungfonden.
Abstract (Originalsprache)
Purpose
To develop and evaluate, in a feasibility study, a computationally efficient image‐reconstruction pipeline for 3D balanced steady state free precession (bSSFP) CINE fetal cardiac MRI that reduces radial streaking artifacts, increases effective temporal resolution, and improves diagnostic image quality compared with previous work.
Methods
Three‐dimensional bSSFP CINE data from 10 volunteers were used. Coil compression was performed using the region‐optimized virtual coils (ROVir) technique and compared with singular value decomposition (SVD) coil compression. For ROVir, the region of interest encompassed the fetal thorax, while the region of interference was positioned over the maternal subcutaneous fat to suppress unwanted signal contributions. Image reconstruction was performed for multiple temporal samplings. Two observers evaluated diagnostic image quality using a visual‐analog scale, and results were analyzed using visual grading characteristics (VGC). Computational efficiency was evaluated using reconstruction runtime and memory usage.
Results
Average 3D CINE acquisition time was 5 min, with a reconstruction time of approximately 5 h for both SVD (8channels and 8 phases) and ROVir (3 channels and 16 phases), with approximately equal memory usage. ROVir enabled higher temporal resolution by reducing the channels required. VGC analysis showed a preference for ROVir across all diagnostic criteria (AUC > 0.5), including edge sharpness, perceived image contrast, artifact suppression, papillary muscles, great vessels, and extracardiac diagnostic image quality, with comparable median scores across temporal samplings.
Conclusion
ROVir coil compression improved diagnostic quality and reduced reconstruction time. By reducing memory demands, reconstruction with a higher number of cardiac phases was also possible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.
- Department of Clinical Physiology, Skåne University Hospital, Lund, Sweden.
- Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund, Sweden.
- Pediatrics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.
- Pediatric Cardiology, Pediatric Heart Centre, Skåne University Hospital, Lund, Sweden.
- Diagnostic Radiology, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.
ORCID-Profile: Marjolein Piek, Johannes Töger, Erik Hedström, Anthony H Aletras
Förderung
- Region Skåne
- Skånes universitetssjukhus
- Hjärt-Lungfonden
- Lund University Medical Faculty Foundation
- Vetenskapsrådet
- Siemens Healthineers
Zitieren
APA
Piek, M., Töger, J., Heiberg, E., Fricke, K., Hedström, E., & Aletras, A. H. (2027). Towards Faster Fetal 3D CINE Cardiac MRI Reconstruction Using Region‐Optimized Virtual Coils ( ROVir ). Magnetic Resonance in Medicine, 97(1), 159-168. https://doi.org/10.1002/mrm.70590
Vancouver
Piek M, Töger J, Heiberg E, Fricke K, Hedström E, Aletras AH. Towards Faster Fetal 3D CINE Cardiac MRI Reconstruction Using Region‐Optimized Virtual Coils ( ROVir ). Magnetic Resonance in Medicine. 2027;97(1):159-168. doi:10.1002/mrm.70590
BibTeX
@article{Piek2027,
author = {Piek, Marjolein and Töger, Johannes and Heiberg, Einar and Fricke, Katrin and Hedström, Erik and Aletras, Anthony H},
title = {Towards Faster Fetal 3D CINE Cardiac MRI Reconstruction Using Region‐Optimized Virtual Coils ( ROVir )},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {159--168},
doi = {10.1002/mrm.70590}
}
EUVIMED