EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Whole‐Brain Diffusion MRI at 7T With Universal Multiband GRAPE pTx Pulses

Marten Laufenberg iD, Daniel Löwen iD, Mónica Ferreira, Nicolas Boulant iD, Jennifer Faber, Tony Stöcker iD

Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 146-158

DOI: 10.1002/mrm.70588 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-09-14. Written by Marten Laufenberg and 5 co-authors. Institution: German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany. Major MEDLINE topics: Diffusion Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. 50 references. The full text is freely available (open access, CC BY 4.0). Funded by: European Union Horizon 2020 Research and Innovation program, German Federal Ministry of Education and Research (BMBF).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To improve signal strength and homogeneity of whole‐brain diffusion‐weighted imaging (DWI) at 7T.

Methods

Universal multiband excitation and refocusing pulses were optimized with the gradient ascent pulse engineering (GRAPE) algorithm across a database of and maps obtained from 20 subjects. Slice‐selective multiband pulses were optimized in a two‐step optimization for transverse and sagittal slice orientations. The optimized pTx pulses were compared to standard circular polarized (CP) pulses in five subjects using a multiband diffusion‐weighted EPI sequence at 1.5 mm isotropic resolution and in one subject at 1.05 mm resolution. The evaluation included Bloch simulations, flip angle mapping, SNR analysis, and diffusion model fitting (DTI and NODDI).

Results

Both GRAPE pulse sets with transverse and sagittal slice orientation improved signal homogeneity and SNR compared to CP pulses across all subjects and head sizes, with particularly high gains in the cerebellum. Sagittal GRAPE pulses yielded the highest mean signal and lowest standard deviation across the brain, while transverse GRAPE pulses provided better cerebellar signal at the cost of signal loss in off‐resonant frontal and temporal regions of large heads. The improved signal translated into more reliable DTI and NODDI fitting, especially in the cerebellum.

Conclusion

Universal multiband GRAPE pTx pulses substantially improve signal homogeneity and SNR in whole‐brain DWI at 7T, enabling more reliable diffusion microstructure mapping, particularly in the cerebellum.

Subjects

MeSH terms (MEDLINE)

Diffusion Magnetic Resonance ImagingBrainImage Processing, Computer-AssistedHumansAlgorithmsSignal-To-Noise RatioMaleAdultFemaleEcho-Planar ImagingComputer Simulation

Author keywords

diffusion MRIparallel transmissionultra‐high field

Authors and institutions

  • German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.
  • Université Paris-Saclay, Commissariat à l'Energie Atomique, CNRS, NeuroSpin, BAOBAB, Gif sur Yvette, France.
  • Department of Parkinson's Disease, Sleep and Movement Disorders, Center of Neurology, University Hospital Bonn, Bonn, Germany.
  • Department of Neuroradiology, University Hospital Bonn, Bonn, Germany.
  • Department of Physics & Astronomy, University of Bonn, Bonn, Germany.

ORCID profiles: Marten Laufenberg, Daniel Löwen, Nicolas Boulant, Tony Stöcker

Funding

  • European Union Horizon 2020 Research and Innovation program
  • German Federal Ministry of Education and Research (BMBF)

Cite

APA

Laufenberg, M., Löwen, D., Ferreira, M., Boulant, N., Faber, J., & Stöcker, T. (2027). Whole‐Brain Diffusion MRI at 7T With Universal Multiband GRAPE pTx Pulses. Magnetic Resonance in Medicine, 97(1), 146-158. https://doi.org/10.1002/mrm.70588

Vancouver

Laufenberg M, Löwen D, Ferreira M, Boulant N, Faber J, Stöcker T. Whole‐Brain Diffusion MRI at 7T With Universal Multiband GRAPE pTx Pulses. Magnetic Resonance in Medicine. 2027;97(1):146-158. doi:10.1002/mrm.70588

BibTeX
@article{Laufenberg2027,
  author = {Laufenberg, Marten and Löwen, Daniel and Ferreira, Mónica and Boulant, Nicolas and Faber, Jennifer and Stöcker, Tony},
  title = {Whole‐Brain Diffusion MRI at 7T With Universal Multiband GRAPE pTx Pulses},
  journal = {Magnetic Resonance in Medicine},
  year = {2027},
  volume = {97},
  number = {1},
  pages = {146--158},
  doi = {10.1002/mrm.70588}
}
Start for free →