Respiratory‐Resolved Isotropic 3D T 1 Mapping of the Carotid Vessel Wall With B 1 + Correction ( CARISMAT1C )
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 133-145
DOI: 10.1002/mrm.70587 ↗At a glance
Journal article in Magnetic Resonance in Medicine, published online on 2026-09-04. Written by Isabel Montón Quesada and 7 co-authors. Institution: Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland. Major MEDLINE topics: Imaging, Three-Dimensional, Carotid Arteries, Magnetic Resonance Angiography, Magnetic Resonance Imaging. 45 references. The full text is freely available (open access, CC BY 4.0). Funded by: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Schweizerische Herzstiftung.
Abstract (original language)
Purpose
To develop, optimize, and characterize a respiratory motion‐resolved free‐running isotropic 3D carotid vessel wall T 1 mapping technique named CARISMAT1C.
Methods
An inversion‐recovery gradient‐echo free‐running pulse sequence with interleaved double flip‐angle (2FA) was implemented, and an extended‐phase‐graph dictionary was used to map the T 1 relaxation time. In a phantom, the T 1 accuracy was compared to that of a single‐flip‐angle (1FA) variant, the inversion‐recovery spin‐echo reference, and clinical routine MOLLI, while the T 1 precision of several phyllotaxis‐based radial trajectories was compared. The most precise sequence was used in 11 healthy volunteers (25 ± 3Y, 3F). A synthetic 3D gray‐blood image was reconstructed from the source images and used to delineate the internal, external, and common carotid arteries. T 1 values across artery sections were compared to those of MOLLI.
Results
In the phantom, the 2FA variant had higher T 1 agreement with the IR‐SE reference than 1FA or MOLLI. The top‐to‐bottom phyllotaxis trajectory with golden‐step shuffling was the most precise and was retained for in vivo scans. End‐expiratory carotid vessel wall T 1 values (1185 ± 42 ms) were similar to those obtained with MOLLI (1162 ± 84 ms, p = 0.37) and showed less intersubject variability and high interscan repeatability. No significant differences were found across arterial segments in the vessel wall T 1 values.
Conclusion
CARISMAT1C had high T 1 accuracy in phantoms and high T 1 precision in vivo in different sections of the carotid artery tree.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland.
ORCID profiles: Isabel Montón Quesada, Pauline Calarnou, Jérôme Yerly, Christopher W Roy, Augustin C Ogier, Ruud B van Heeswijk
Funding
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Schweizerische Herzstiftung
Cite
APA
Montón Quesada, I., Hirsch, C., Calarnou, P., Ledoux, J. B., Yerly, J., Roy, C. W., Ogier, A. C., & van Heeswijk, R. B. (2027). Respiratory‐Resolved Isotropic 3D T 1 Mapping of the Carotid Vessel Wall With B 1 + Correction ( CARISMAT1C ). Magnetic Resonance in Medicine, 97(1), 133-145. https://doi.org/10.1002/mrm.70587
Vancouver
Montón Quesada I, Hirsch C, Calarnou P, Ledoux JB, Yerly J, Roy CW, et al. Respiratory‐Resolved Isotropic 3D T 1 Mapping of the Carotid Vessel Wall With B 1 + Correction ( CARISMAT1C ). Magnetic Resonance in Medicine. 2027;97(1):133-145. doi:10.1002/mrm.70587
BibTeX
@article{MontnQuesada2027,
author = {Montón Quesada, Isabel and Hirsch, Céline and Calarnou, Pauline and Ledoux, Jean-Baptiste and Yerly, Jérôme and Roy, Christopher W and Ogier, Augustin C and van Heeswijk, Ruud B},
title = {Respiratory‐Resolved Isotropic 3D T 1 Mapping of the Carotid Vessel Wall With B 1 + Correction ( CARISMAT1C )},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {133--145},
doi = {10.1002/mrm.70587}
}
EUVIMED