EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Respiratory‐Resolved Isotropic 3D T 1 Mapping of the Carotid Vessel Wall With B 1 + Correction ( CARISMAT1C )

Isabel Montón Quesada iD, Céline Hirsch, Pauline Calarnou iD, Jean-Baptiste Ledoux, Jérôme Yerly iD, Christopher W Roy iD, Augustin C Ogier iD, Ruud B van Heeswijk iD

Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 133-145

DOI: 10.1002/mrm.70587 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-09-04. Written by Isabel Montón Quesada and 7 co-authors. Institution: Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland. Major MEDLINE topics: Imaging, Three-Dimensional, Carotid Arteries, Magnetic Resonance Angiography, Magnetic Resonance Imaging. 45 references. The full text is freely available (open access, CC BY 4.0). Funded by: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Schweizerische Herzstiftung.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To develop, optimize, and characterize a respiratory motion‐resolved free‐running isotropic 3D carotid vessel wall T 1 mapping technique named CARISMAT1C.

Methods

An inversion‐recovery gradient‐echo free‐running pulse sequence with interleaved double flip‐angle (2FA) was implemented, and an extended‐phase‐graph dictionary was used to map the T 1 relaxation time. In a phantom, the T 1 accuracy was compared to that of a single‐flip‐angle (1FA) variant, the inversion‐recovery spin‐echo reference, and clinical routine MOLLI, while the T 1 precision of several phyllotaxis‐based radial trajectories was compared. The most precise sequence was used in 11 healthy volunteers (25 ± 3Y, 3F). A synthetic 3D gray‐blood image was reconstructed from the source images and used to delineate the internal, external, and common carotid arteries. T 1 values across artery sections were compared to those of MOLLI.

Results

In the phantom, the 2FA variant had higher T 1 agreement with the IR‐SE reference than 1FA or MOLLI. The top‐to‐bottom phyllotaxis trajectory with golden‐step shuffling was the most precise and was retained for in vivo scans. End‐expiratory carotid vessel wall T 1 values (1185 ± 42 ms) were similar to those obtained with MOLLI (1162 ± 84 ms, p = 0.37) and showed less intersubject variability and high interscan repeatability. No significant differences were found across arterial segments in the vessel wall T 1 values.

Conclusion

CARISMAT1C had high T 1 accuracy in phantoms and high T 1 precision in vivo in different sections of the carotid artery tree.

Subjects

MeSH terms (MEDLINE)

Imaging, Three-DimensionalCarotid ArteriesMagnetic Resonance AngiographyMagnetic Resonance ImagingHumansPhantoms, ImagingAdultMaleFemaleAlgorithmsReproducibility of ResultsRespirationHealthy VolunteersImage Processing, Computer-Assisted

Author keywords

3D T1 mappingB1+ correctioncarotid arteryfree‐runningrespiratory‐resolved

Authors and institutions

  • Department of Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
  • CIBM Center for Biomedical Imaging, Lausanne, Switzerland.

ORCID profiles: Isabel Montón Quesada, Pauline Calarnou, Jérôme Yerly, Christopher W Roy, Augustin C Ogier, Ruud B van Heeswijk

Funding

  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
  • Schweizerische Herzstiftung

Cite

APA

Montón Quesada, I., Hirsch, C., Calarnou, P., Ledoux, J. B., Yerly, J., Roy, C. W., Ogier, A. C., & van Heeswijk, R. B. (2027). Respiratory‐Resolved Isotropic 3D T 1 Mapping of the Carotid Vessel Wall With B 1 + Correction ( CARISMAT1C ). Magnetic Resonance in Medicine, 97(1), 133-145. https://doi.org/10.1002/mrm.70587

Vancouver

Montón Quesada I, Hirsch C, Calarnou P, Ledoux JB, Yerly J, Roy CW, et al. Respiratory‐Resolved Isotropic 3D T 1 Mapping of the Carotid Vessel Wall With B 1 + Correction ( CARISMAT1C ). Magnetic Resonance in Medicine. 2027;97(1):133-145. doi:10.1002/mrm.70587

BibTeX
@article{MontnQuesada2027,
  author = {Montón Quesada, Isabel and Hirsch, Céline and Calarnou, Pauline and Ledoux, Jean-Baptiste and Yerly, Jérôme and Roy, Christopher W and Ogier, Augustin C and van Heeswijk, Ruud B},
  title = {Respiratory‐Resolved Isotropic 3D T 1 Mapping of the Carotid Vessel Wall With B 1 + Correction ( CARISMAT1C )},
  journal = {Magnetic Resonance in Medicine},
  year = {2027},
  volume = {97},
  number = {1},
  pages = {133--145},
  doi = {10.1002/mrm.70587}
}
Start for free →