EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

OpenMRF : A Modular, Vendor‐Neutral Open‐Source Framework for Magnetic Resonance Fingerprinting Using Pulseq

Tom Griesler iD, Jannik Stebani iD, Sydney Kaplan iD, Ivaylo Angelov, Petra Albert iD, Tobias Wech iD, Martin Blaimer iD, Xiang Wang, Qingping Chen iD, Maxim Zaitsev, Zhibo Zhu, Qi Liu and 6 more

Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 114-132

DOI: 10.1002/mrm.70586 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-09-06. Written by Tom Griesler and 17 co-authors. Institution: Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA. Major MEDLINE topics: Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Cited 1 times so far (Crossref); 68 references. The full text is freely available (open access, CC BY 4.0). Funded by: NHLBI NIH HHS, Deutsche Forschungsgemeinschaft, NIH HHS.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

Widespread adoption and methodological advancement of magnetic resonance fingerprinting (MRF) are limited by the lack of unified, reproducible implementation frameworks and fragmented open‐source tools. To address these barriers, we introduce OpenMRF—a comprehensive Pulseq‐based solution—designed to enable standardized and transferable MRF research across vendors, sites, and field strengths.

Methods

OpenMRF integrates modular Pulseq‐based sequence design, Bloch‐equation‐based dictionary generation directly from . seq files, and iterative low‐rank subspace reconstruction. The framework was evaluated through digital phantom simulations, a multi‐site ISMRM/NIST phantom study on Siemens MRI systems at 0.55, 1.5, and 3 T, as well as GE and United Imaging 3 T platforms, and representative in vivo acquisitions in the liver (0.55 T), myocardium (1.5 T), and brain (3 T).

Results

Simulations demonstrated high mapping accuracy in an ISMRM/NIST‐like digital phantom, with low‐rank reconstruction yielding deviations of 0.03% ± 0.32% (T 1 ) and 0.12% ± 1.94% (T 2 ). The multi‐site phantom study yielded relaxation times consistent with reference values at all field strengths, with mean deviations of −0.1% ± 2.9% (T 1 ), −1.5% ± 8.7% (T 2 ), and −4.0% ± 7.2% (T 1ρ ). In vivo acquisitions produced high‐quality parameter maps across different anatomical applications and field strengths.

Conclusion

OpenMRF provides a robust, open‐source, end‐to‐end Pulseq‐based solution for MRF designed to enable reproducible sequence implementation, physics‐accurate dictionary simulation, and advanced reconstruction across vendors and field strengths. By providing a unified platform for method development, comparison, and cross‐vendor application, OpenMRF aims to accelerate reproducible and harmonized quantitative MRI research within the community.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedPhantoms, ImagingBrainAlgorithmsHumansSoftwareHeartLiverReproducibility of ResultsComputer Simulation

Author keywords

MRFPulseqT1ρcross‐vendoropen‐sourcequantitative MRI

Authors and institutions

  • Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
  • Experimental Physics 5, University of Würzburg, Würzburg, Germany.
  • Magnetic Resonance and X-Ray Imaging Department, Fraunhofer Institute for Integrated Circuits IIS, Division Development Center X-Ray Technology, Würzburg, Germany.
  • Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany.
  • Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.

ORCID profiles: Tom Griesler, Jannik Stebani, Sydney Kaplan, Petra Albert, Tobias Wech, Martin Blaimer, Qingping Chen, Jon-Fredrik Nielsen, Jesse I Hamilton, Peter Nordbeck, Nicole Seiberlich, Maximilian Gram

Funding

  • NHLBI NIH HHS
  • Deutsche Forschungsgemeinschaft
  • NIH HHS
  • NINDS NIH HHS
  • Siemens Healthineers
  • NIBIB NIH HHS
  • European Association of National Metrology Institutes
  • European Commission

Cite

APA

Griesler, T., Stebani, J., Kaplan, S., Angelov, I., Albert, P., Wech, T., Blaimer, M., Wang, X., Chen, Q., Zaitsev, M., Zhu, Z., Liu, Q., Martin, P., Nielsen, J. F., Hamilton, J. I., Nordbeck, P., Seiberlich, N., & Gram, M. (2027). OpenMRF : A Modular, Vendor‐Neutral Open‐Source Framework for Magnetic Resonance Fingerprinting Using Pulseq. Magnetic Resonance in Medicine, 97(1), 114-132. https://doi.org/10.1002/mrm.70586

Vancouver

Griesler T, Stebani J, Kaplan S, Angelov I, Albert P, Wech T, et al. OpenMRF : A Modular, Vendor‐Neutral Open‐Source Framework for Magnetic Resonance Fingerprinting Using Pulseq. Magnetic Resonance in Medicine. 2027;97(1):114-132. doi:10.1002/mrm.70586

BibTeX
@article{Griesler2027,
  author = {Griesler, Tom and Stebani, Jannik and Kaplan, Sydney and Angelov, Ivaylo and Albert, Petra and Wech, Tobias and Blaimer, Martin and Wang, Xiang and Chen, Qingping and Zaitsev, Maxim and Zhu, Zhibo and Liu, Qi and Martin, Peter and Nielsen, Jon-Fredrik and Hamilton, Jesse I and Nordbeck, Peter and Seiberlich, Nicole and Gram, Maximilian},
  title = {OpenMRF : A Modular, Vendor‐Neutral Open‐Source Framework for Magnetic Resonance Fingerprinting Using Pulseq},
  journal = {Magnetic Resonance in Medicine},
  year = {2027},
  volume = {97},
  number = {1},
  pages = {114--132},
  doi = {10.1002/mrm.70586}
}
Start for free →