Motion‐Robust Approach for 4D Cardiac Cine Using 2D Real‐Time Acquisitions and Slice‐to‐Volume Reconstruction
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 57-69
DOI: 10.1002/mrm.70570 ↗At a glance
Journal article in Magnetic Resonance in Medicine, published online on 2026-08-19. Written by Ye Tian and 4 co-authors. Institution: Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, Californ…. Major MEDLINE topics: Magnetic Resonance Imaging, Cine, Heart, Imaging, Three-Dimensional, Image Processing, Computer-Assisted. 48 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: NICHD NIH HHS, NIH HHS, NHLBI NIH HHS.
Abstract (original language)
Purpose
4D cardiac cine is a powerful tool for comprehensive cardiac function assessment; however, current methods rely on regular breathing and are sensitive to bulk motion and arrhythmia. We aim to develop a 4D cardiac cine approach that requires no patient cooperation and is robust to irregular breathing, bulk motion, and cardiac arrhythmia.
Methods
2D real‐time (RT) spiral bSSFP with synchronized ECG was acquired in 4 cardiac orientations. In each orientation, the 2D slice was “swept” across the heart to provide volume coverage. Retrospectively gated slice‐to‐volume reconstruction (SVR) was then performed to reconstruct 4D cine with 1 mm 3 voxel size and 25 cardiac phases. RT‐SVR and clinical standard breath‐hold short‐axis cine were acquired in 19 subjects, including 4 arrhythmia and 2 myocardial infarction patients. Biventricular volumes were measured, and blood‐myocardium contrast and boundary sharpness scores were compared.
Results
The RT‐SVR approach successfully provided 4D cardiac cine for all subjects. Acquisition time was 8:33 ± 1:01 min and 8:27 ± 2:06 min ( p = 0.85), blood‐myocardium contrast ratio was 2.30 ± 0.58 and 2.38 ± 0.59 ( p = 0.33), boundary sharpness was 1.11 ± 0.46 and 1.18 ± 0.53 ( p = 0.04), for RT‐SVR and breath‐hold cine, respectively. Bi‐ventricular volumes had good agreement, with an ejection fraction bias of −4.02% ( p < 0.05) and −2.30% ( p = 0.10) for left and right ventricles, respectively.
Conclusion
The RT‐SVR approach enables 4D cardiac cine with comparable bi‐ventricular volumes, contrast, sharpness, and acquisition time compared to standard breath‐hold cine while providing additional motion robustness. This approach may be beneficial in patients that are non‐cooperative, children, and those with irregular breathing and/or arrhythmia.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.
- Pediatrics and Radiology, Children's Hospital Los Angeles, Los Angeles, California, USA.
ORCID profiles: Ye Tian, Anand A Joshi, Jon A Detterich, John C Wood, Krishna S Nayak
Funding
- NICHD NIH HHS
- NIH HHS
- NHLBI NIH HHS
- Society for Cardiovascular Magnetic Resonance, Seed Grant 2024
- National Institutes of Health
- Society for Cardiovascular Magnetic Resonance
Cite
APA
Tian, Y., Joshi, A. A., Detterich, J. A., Wood, J. C., & Nayak, K. S. (2027). Motion‐Robust Approach for 4D Cardiac Cine Using 2D Real‐Time Acquisitions and Slice‐to‐Volume Reconstruction. Magnetic Resonance in Medicine, 97(1), 57-69. https://doi.org/10.1002/mrm.70570
Vancouver
Tian Y, Joshi AA, Detterich JA, Wood JC, Nayak KS. Motion‐Robust Approach for 4D Cardiac Cine Using 2D Real‐Time Acquisitions and Slice‐to‐Volume Reconstruction. Magnetic Resonance in Medicine. 2027;97(1):57-69. doi:10.1002/mrm.70570
BibTeX
@article{Tian2027,
author = {Tian, Ye and Joshi, Anand A and Detterich, Jon A and Wood, John C and Nayak, Krishna S},
title = {Motion‐Robust Approach for 4D Cardiac Cine Using 2D Real‐Time Acquisitions and Slice‐to‐Volume Reconstruction},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {57--69},
doi = {10.1002/mrm.70570}
}
EUVIMED