Generalized inhomogeneity‐resilient relaxation along a fictitious field (girRAFF) for improved robustness in rotating frame relaxometry at 3T
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30219 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Chiara Coletti und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Phantoms, Imaging, Algorithms. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nederlandse Organisatie voor Wetenschappelijk Onderzoek, TU Delft - Erasmus MC Convergence Impulse Award, 4TU Precision Medicine program supported by High Tech for a Sustainable Future.
Abstract (Originalsprache)
Purpose
To optimize Relaxation along a Fictitious Field (RAFF) pulses for rotating frame relaxometry with improved robustness in the presence of and field inhomogeneities.
Methods
The resilience of RAFF pulses against and inhomogeneities was studied using Bloch simulations. A parameterized extension of the RAFF formulation was introduced and used to derive a generalized inhomogeneity‐resilient RAFF (girRAFF) pulse. RAFF and girRAFF preparation efficiency, defined as the ratio of the longitudinal magnetization before and after the preparation (), were simulated and validated in phantom experiments. and parametric maps were acquired at 3T in phantom, the calf muscle, and the knee cartilage of healthy subjects. The relaxation time maps were analyzed for resilience against artificially induced field inhomogeneities and assessed in terms of in vivo reproducibility.
Results
Optimized girRAFF preparations yielded improved preparation efficiency (0.95/0.91 simulations/phantom) with respect to RAFF (0.36/0.67 simulations/phantom). preparations showed in phantom/calf 6.0/4.8 times higher resilience to inhomogeneities than RAFF, and a 4.7/5.3 improved resilience to inhomogeneities. In the knee cartilage, (53 14 ms) was higher than (42 11 ms). Moreover, girRAFF preparations yielded 7.6/4.9 times improved reproducibility across / inhomogeneity conditions, 1.9 times better reproducibility across subjects and 1.2 times across slices compared with RAFF. Dixon‐based fat suppression led to a further 15‐fold improvement in the robustness of girRAFF to inhomogeneities.
Conclusions
RAFF pulses display residual sensitivity to off‐resonance and pronounced sensitivity to inhomogeneities. Optimized girRAFF pulses provide increased robustness and may be an appealing alternative for applications where resilience against field inhomogeneities is required.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
- HollandPTC, Delft, The Netherlands.
ORCID-Profile: Chiara Coletti, Joao Tourais, Sebastian Weingärtner
Förderung
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
- TU Delft - Erasmus MC Convergence Impulse Award
- 4TU Precision Medicine program supported by High Tech for a Sustainable Future
- ZonMw
- European Research Council
Zitieren
APA
Coletti, C., Naaktgeboren, R., Tourais, J., Van De Steeg-Henzen, C., & Weingärtner, S. (2024). Generalized inhomogeneity‐resilient relaxation along a fictitious field (girRAFF) for improved robustness in rotating frame relaxometry at 3T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30219
Vancouver
Coletti C, Naaktgeboren R, Tourais J, Van De Steeg-Henzen C, Weingärtner S. Generalized inhomogeneity‐resilient relaxation along a fictitious field (girRAFF) for improved robustness in rotating frame relaxometry at 3T. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30219
BibTeX
@article{Coletti2024,
author = {Coletti, Chiara and Naaktgeboren, Roeland and Tourais, Joao and Van De Steeg-Henzen, Christal and Weingärtner, Sebastian},
title = {Generalized inhomogeneity‐resilient relaxation along a fictitious field (girRAFF) for improved robustness in rotating frame relaxometry at 3T},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30219}
}
EUVIMED