Joint Reconstruction of Multiple b ‐Values and Multiple Directions for Accelerating Diffusion Kurtosis Imaging
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70513 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Jian Lyu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of the Radiation Oncology Physics, Foshan Key Laboratory of Precision Therapy in Oncology and Neurology, The First People's Hospital of Fo…. Hauptthemen laut MEDLINE: Image Enhancement, Diffusion Magnetic Resonance Imaging. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: GuangDong Province Health Bureau, Fo Shan Shi Zi Chou Jing Fei Lei Ke Ji Chuang Xin Xiang Mu, CAS Superconducting Research Project.
Abstract (Originalsprache)
Purpose
While multishot interleaved echo‐planar imaging (iEPI) enables higher resolution diffusion kurtosis imaging (DKI) compared to single‐shot EPI, its clinical application is hindered by the lengthy acquisition time. This study proposes a novel model‐based reconstruction approach to accelerate iEPI DKI acquisition. Theory and Methods The proposed model‐based framework directly estimates DKI tensors from k‐space data through joint reconstruction of all k‐space data across multiple b values and diffusion directions. It incorporates the intrinsic DKI signal model as a prior and integrates two key components: (1) total variation (TV) regularization to suppress noise in DKI tensor maps, and (2) a physically relevant (PhyR) constraint to ensure biologically plausible parameter estimates, termed mDKI‐TV‐PhyR. The performance of mDKI‐TV‐PhyR is compared with its two variants (mDKI and mDKI‐TV) and conventional reconstruction‐fitting pipelines using both simulated and in vivo data with 4‐fold in‐plane undersampling.
Results
Compared to the conventional methods, the proposed mDKI‐TV‐PhyR method achieves lower RMSE for all DKI parameters. Bland–Altman analysis shows the smallest bias for FA and MK, as well as the narrowest limits of agreement for FA and MD. Compared to mDKI‐TV, mDKI‐TV‐PhyR produces MK maps without “black holes,” exhibits improved stability across all DKI parameters, and achieves lower FA bias.
Conclusion
The proposed method shows substantial promise for clinical applications where both temporal efficiency and spatial resolution are paramount.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of the Radiation Oncology Physics, Foshan Key Laboratory of Precision Therapy in Oncology and Neurology, The First People's Hospital of Foshan (The Affiliated Foshan Hospital of Southern University of Science…
- Clinical Research Center, Foshan Key Laboratory of Precision Therapy in Oncology and Neurology, The First People's Hospital of Foshan (The Affiliated Foshan Hospital of Southern University of Science and Technology), Sc…
- Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
- Department of Radiotherapy, Guangdong Academy of Medical Sciences, Guangdong General Hospital, Guangzhou, Guangdong, China.
- Department of Radiology, The First People's Hospital of Foshan (The Affiliated Foshan Hospital of Southern University of Science and Technology), School of Medicine, Southern University of Science and Technology, Foshan…
- Institute of Research and Clinical Innovations, Neusoft Medical Systems Co., Ltd., Hangzhou, Zhejiang, China.
ORCID-Profile: Li Guo, Zhifeng Xu, Hua Guo
Förderung
- GuangDong Province Health Bureau
- Fo Shan Shi Zi Chou Jing Fei Lei Ke Ji Chuang Xin Xiang Mu
- CAS Superconducting Research Project
- Guangdong Basic and Applied Basic Research Foundation
- National Natural Science Foundation of China
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Lyu, J., Guo, L., Zhong, W., Xu, Z., Zhao, H., Gao, M., Xu, Z., Chen, Z., & Guo, H. (2026). Joint Reconstruction of Multiple b ‐Values and Multiple Directions for Accelerating Diffusion Kurtosis Imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70513
Vancouver
Lyu J, Guo L, Zhong W, Xu Z, Zhao H, Gao M, et al. Joint Reconstruction of Multiple b ‐Values and Multiple Directions for Accelerating Diffusion Kurtosis Imaging. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70513
BibTeX
@article{Lyu2026,
author = {Lyu, Jian and Guo, Li and Zhong, Wen and Xu, Zhongbiao and Zhao, Hai and Gao, Mingyong and Xu, Zhifeng and Chen, Zhifeng and Guo, Hua},
title = {Joint Reconstruction of Multiple b ‐Values and Multiple Directions for Accelerating Diffusion Kurtosis Imaging},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70513}
}
EUVIMED