Localized Quadratic RF Encoded Spin‐Echo With Spiral‐ PRIME Reconstruction: A Practical Alternative to 3D FSE for High‐Resolution Volumetric Brain MRI
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70476 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Guruprasad Krishnamoorthy und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Image Processing, Computer-Assisted. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Purpose
To extend localized quadratic (LQ) RF encoded spin‐echo imaging with acquisition and reconstruction strategies that improve efficiency and artifact robustness, positioning it as a practical alternative to 3D FSE for high‐resolution volumetric brain MRI.
Methods
The framework integrates (1) additional gradient‐echo readouts for simultaneous T2*w or PDw with T2w without prolonging scan time, (2) an in‐plane sampling scheme that distributes arms across shot/trajectory types to maximize k‐space coverage and render phase inconsistencies as incoherent residue, (3) sliding‐slice encoding to disperse through‐plane artifacts, (4) a novel loop‐ordering to avoid repeated startup cycles and improve motion robustness, and (5) a hybrid 2D/3D Physics‐based Reconstruction with Iterative Model‐based Enhancement (spiral‐PRIME) performing deblurring, fat–water separation, and 3D wavelet denoising. Healthy‐volunteer imaging (3 T) was compared with fully sampled LQ and conventional 3D FSE using peak signal‐to‐noise ratio, structural similarity index measure, pseudo‐replica SNR gain, and qualitative review.
Results
Sliding‐slice with loop‐ordering reduced through‐plane artifacts and improved temporal efficiency, while in‐plane sampling dispersed trajectory inconsistencies as incoherent noise. Spiral‐PRIME suppressed undersampling artifacts and noise while preserving fine structure. Relative to spiral‐SENSE, spiral‐PRIME achieved consistent T2w SNR gains of ∼30%–40% in WM/GM and substantially higher gains for T2*w, with CNR improvements most pronounced for GM–WM. Despite R ≈ 2.33 undersampling, reconstructions closely matched fully sampled references and delivered quality comparable to or exceeding 3D FSE.
Conclusion
LQ spin‐echo with spiral‐PRIME enables efficient, multi‐contrast volumetric brain imaging with robust artifact suppression and clinically meaningful SNR/CNR gains, supporting its potential as a practical alternative to 3D FSE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
ORCID-Profile: Julia V Velikina
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Krishnamoorthy, G., Velikina, J. V., & Pipe, J. G. (2026). Localized Quadratic RF Encoded Spin‐Echo With Spiral‐ PRIME Reconstruction: A Practical Alternative to 3D FSE for High‐Resolution Volumetric Brain MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70476
Vancouver
Krishnamoorthy G, Velikina JV, Pipe JG. Localized Quadratic RF Encoded Spin‐Echo With Spiral‐ PRIME Reconstruction: A Practical Alternative to 3D FSE for High‐Resolution Volumetric Brain MRI. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70476
BibTeX
@article{Krishnamoorthy2026,
author = {Krishnamoorthy, Guruprasad and Velikina, Julia V and Pipe, James G},
title = {Localized Quadratic RF Encoded Spin‐Echo With Spiral‐ PRIME Reconstruction: A Practical Alternative to 3D FSE for High‐Resolution Volumetric Brain MRI},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70476}
}
EUVIMED