A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT ‐Cardiac MRF
Magnetic Resonance in Medicine · 2026-10 · 96 (4) · 1806-1813
DOI: 10.1002/mrm.70470 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 01.07.2026. Verfasst von Sydney Kaplan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Heart, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens Healthineers, NIA NIH HHS, NIDDK NIH HHS.
Abstract (Originalsprache)
Purpose
To evaluate the impact of explicitly modeling Magnetization Transfer (MT) during reconstruction of cardiac Magnetic Resonance Fingerprinting (cMRF) maps on T 1 and T 2 quantification. Methods cMRF data were reconstructed using two dictionaries: a conventional cMRF dictionary that ignores MT processes, and an MT‐cMRF dictionary modeling T 1 and T 2 of the free water pool ( T 1f and T 2f , respectively), as well as the bound pool fraction (BPF) as free parameters. Measurements which include MT processes were assessed in simulation and phantom to ensure that T 1f , T 2f , and BPF could accurately be measured using cMRF. cMRF data were then collected in 14 healthy subjects to measure T 1 / T 1f , T 2 / T 2f , and BPF in normal myocardium. Finally, cMRF data were acquired in five patients with known or suspected myocardial scar at 1.5T, and tissue property maps both ignoring and including MT were generated. Linear discriminant analyses (LDA) were performed to assess differences in tissue property values between scar and remote myocardium.
Results
MT‐cMRF showed excellent agreement with ground truth simulations (RMS error = 2.4% ± 3.9%) and phantom measurements ( R 2 = 0.99). Values measured with MT‐cMRF in healthy subjects ( T 1f = 1137 ± 72 ms, T 2f = 42.8 ± 4.2 ms, BPF = 8.2% ± 1.2%) were significantly different than conventional cMRF ( T 1 = 947 ± 75 ms, T 2 = 41.5 ± 3.9 ms). T 1f / T 2f and T 2f /BPF from MT‐cMRF demonstrated higher LDA accuracy (82.4% and 86.1%) in discriminating scar from healthy tissue than T 1 and T 2 from conventional cMRF (61.8%).
Conclusion
Incorporating MT modeling into cMRF results in improved T 1f and T 2f quantification compared to conventional modeling and enables BPF measurement. Native MT‐cMRF T 1f , T 2f , and BPF values showed differences between scar and healthy myocardium.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Imaging Physics and Engineering, King's College London, London, UK.
- Frankel Cardiovascular Center, Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA.
ORCID-Profile: Sydney Kaplan, Jesse Hamilton, Shaihan Malik
Förderung
- Siemens Healthineers
- NIA NIH HHS
- NIDDK NIH HHS
- Division of Cancer Prevention, National Cancer Institute
- NHLBI NIH HHS
- NCI NIH HHS
- American Heart Association
- National Institute on Aging
Zitieren
APA
Kaplan, S., Liu, Z., Hamilton, J., Malik, S., Madamanchi, C., Murthy, V., Swanson, S., & Seiberlich, N. (2026). A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT ‐Cardiac MRF. Magnetic Resonance in Medicine, 96(4), 1806-1813. https://doi.org/10.1002/mrm.70470
Vancouver
Kaplan S, Liu Z, Hamilton J, Malik S, Madamanchi C, Murthy V, et al. A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT ‐Cardiac MRF. Magnetic Resonance in Medicine. 2026;96(4):1806-1813. doi:10.1002/mrm.70470
BibTeX
@article{Kaplan2026,
author = {Kaplan, Sydney and Liu, Zexuan and Hamilton, Jesse and Malik, Shaihan and Madamanchi, Chaitanya and Murthy, Venkatesh and Swanson, Scott and Seiberlich, Nicole},
title = {A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT ‐Cardiac MRF},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {4},
pages = {1806--1813},
doi = {10.1002/mrm.70470}
}