High‐Temporal‐Resolution Monitoring of Creatine and Phosphocreatine Dynamics in Skeletal Muscle Using Ultrafast Z‐Spectroscopy ( UFZ ) CEST MRI at 3T
Magnetic Resonance in Medicine · 2026-10 · 96 (4) · 1798-1805
DOI: 10.1002/mrm.70464 ↗At a glance
Journal article in Magnetic Resonance in Medicine, published online on 2026-06-05. Written by Licheng Ju and 6 co-authors. Institution: F.M. Kirby Research Center For Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA. Major MEDLINE topics: Phosphocreatine, Creatine, Muscle, Skeletal, Magnetic Resonance Imaging. 54 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIBIB NIH HHS, NIA NIH HHS, NIH HHS.
Abstract (original language)
Purpose
To evaluate the feasibility of High‐Temporal‐Resolution (HTR) Ultrafast Z‐spectrum (UFZ) CEST MRI for monitoring the dynamic fluctuations of phosphocreatine (PCr) and creatine (Cr) in human skeletal muscle (SM) at 3 T during and after exercise.
Methods
HTR UFZ‐CEST MRI of SM was achieved using a 1D spatial and spectral encoding with a 2D turbo spin‐echo readout. Five healthy subjects performed in‐magnet plantar flexion exercise, and dynamic changes in Amide, PCr, and partial PCr‐mixed creatine (Cr + ) CEST signals were quantified using the Polynomial and Lorentzian Line‐shape Fitting (PLOF) method. This approach enables monitoring of PCr/Cr CEST dynamics throughout exercise and recovery.
Results
Dynamic CEST contrasts with 7.6 s temporal resolution revealed PCr depletion (−76.9% ± 17.7%) and concomitant Cr elevation (469.0% ± 116.3%) during exercise, followed by exponential PCr recovery and Cr decay during recovery. The post‐exercise recovery constants for Cr and PCr CEST were 61.5 ± 45.6 s and 73.3 ± 66.1 s, respectively. Using two‐step Bloch‐McConnell simulation based on the experimental lineshape and CEST changes, we estimated an exchange rate of 150 ± 70 s −1 for CrCEST and 185 ± 105 s −1 for PCrCEST in the resting state.
Conclusion
These results establish UFZ‐CEST as a rapid, noninvasive method for mapping Cr/PCr dynamics in human SM and provide a foundation for clinical assessment of mitochondrial function.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- F.M. Kirby Research Center For Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA.
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA.
ORCID profiles: T Jake Samuel, Kexin Wang, Jiadi Xu
Funding
- NIBIB NIH HHS
- NIA NIH HHS
- NIH HHS
- NICHD NIH HHS
- NHLBI NIH HHS
- National Institutes of Health
Cite
APA
Ju, L., Samuel, T. J., Schär, M., Wang, K., Wu, Y., Weiss, R. G., & Xu, J. (2026). High‐Temporal‐Resolution Monitoring of Creatine and Phosphocreatine Dynamics in Skeletal Muscle Using Ultrafast Z‐Spectroscopy ( UFZ ) CEST MRI at 3T. Magnetic Resonance in Medicine, 96(4), 1798-1805. https://doi.org/10.1002/mrm.70464
Vancouver
Ju L, Samuel TJ, Schär M, Wang K, Wu Y, Weiss RG, et al. High‐Temporal‐Resolution Monitoring of Creatine and Phosphocreatine Dynamics in Skeletal Muscle Using Ultrafast Z‐Spectroscopy ( UFZ ) CEST MRI at 3T. Magnetic Resonance in Medicine. 2026;96(4):1798-1805. doi:10.1002/mrm.70464
BibTeX
@article{Ju2026,
author = {Ju, Licheng and Samuel, T Jake and Schär, Michael and Wang, Kexin and Wu, Yihan and Weiss, Robert G and Xu, Jiadi},
title = {High‐Temporal‐Resolution Monitoring of Creatine and Phosphocreatine Dynamics in Skeletal Muscle Using Ultrafast Z‐Spectroscopy ( UFZ ) CEST MRI at 3T},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {4},
pages = {1798--1805},
doi = {10.1002/mrm.70464}
}
EUVIMED