Concomitant Gradient Effects Across Field Strengths and Gradient Amplitudes: Improved Estimation of Errors and Correction of Concomitant Dephasing and Diffusion Weighting
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70422 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Viktor Olsson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Radiation Physics, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swedish Research Council, Swedish Cancer Society, eSSENCE@LU: the e-Science Collaboration.
Abstract (Originalsprache)
Purpose
Deleterious effects from concomitant gradients are amplified at lower field strengths and stronger gradients. We aimed to show the signal errors caused by concomitant gradients across a wide range of hardware configurations and propose corrections that can be applied during experimental design and analysis. Theory and Methods We derived a compact but accurate expression for concomitant gradients and simulated the associated signal bias across field strengths (0.03‐7 T) and gradient amplitudes (20‐600 mT/m) for asymmetric Maxwell‐compensated diffusion encoding gradient waveforms. Bias was assigned to “concomitant dephasing” or “concomitant diffusion weighting.” Concomitant dephasing was reduced by waveform correction that was deployed in the design stage. Concomitant diffusion weighting could be accounted for by using the actual gradient waveform during analysis.
Results
Concomitant dephasing was caused by loss of Maxwell compensation during waveform resampling, with signal errors up to 100%, especially at low B 0 and high g max . Our waveform correction yielded a categorical improvement to signal accuracy, reducing bias to < 1% for most systems. However, bias at extreme B 0 ‐ g max ‐combinations remained > 1% (e.g., B 0 = 3 T and g max = 600 mT/m). Concomitant diffusion weighting caused biases above 1% at across all simulated MRI systems.
Conclusion
Concomitant gradients have a relevant impact on signal accuracy, especially at low fields and ultra‐strong gradients. Concomitant dephasing must be considered for asymmetric waveforms, but can be largely suppressed by our correction method. Concomitant diffusion weighting is always present, regardless of waveform symmetry, but has a smaller impact and can be accounted for in the analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Radiation Physics, Lund University, Lund, Sweden.
- Siemens Healthcare AB, Malmö, Sweden.
ORCID-Profile: Viktor Olsson, Felix Mortensen, Emil Ljungberg, Frederik Testud, Ronnie Wirestam, Malwina Molendowska, Filip Szczepankiewicz
Förderung
- Swedish Research Council
- Swedish Cancer Society
- eSSENCE@LU: the e-Science Collaboration
- Swedish Prostate Cancer Federation
- Crafoord Foundation
- Vetenskapsrådet
- Cancerfonden
- Crafoordska Stiftelsen
Zitieren
APA
Olsson, V., Mortensen, F., Ljungberg, E., Testud, F., Wirestam, R., Molendowska, M., & Szczepankiewicz, F. (2026). Concomitant Gradient Effects Across Field Strengths and Gradient Amplitudes: Improved Estimation of Errors and Correction of Concomitant Dephasing and Diffusion Weighting. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70422
Vancouver
Olsson V, Mortensen F, Ljungberg E, Testud F, Wirestam R, Molendowska M, et al. Concomitant Gradient Effects Across Field Strengths and Gradient Amplitudes: Improved Estimation of Errors and Correction of Concomitant Dephasing and Diffusion Weighting. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70422
BibTeX
@article{Olsson2026,
author = {Olsson, Viktor and Mortensen, Felix and Ljungberg, Emil and Testud, Frederik and Wirestam, Ronnie and Molendowska, Malwina and Szczepankiewicz, Filip},
title = {Concomitant Gradient Effects Across Field Strengths and Gradient Amplitudes: Improved Estimation of Errors and Correction of Concomitant Dephasing and Diffusion Weighting},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70422}
}
EUVIMED