EUVIMEDDescoperă EUVIMED
Open access · CC BY 4.0

Effect of Water Suppression and Metabolite Cycling on Quantification of 1 H MRS Spectra in the Human Brain at 3 Tesla

Dinesh K Deelchand iD, Pierre-Gilles Henry

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 542-547

DOI: 10.1002/mrm.70352 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-03-19. Written by Dinesh K Deelchand and 1 co-authors. Institution: Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA. Major MEDLINE topics: Water, Brain, Proton Magnetic Resonance Spectroscopy. Cited 2 times so far (Crossref); 32 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIBIB NIH HHS, NIH HHS, National Institutes of Health.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Purpose

This study investigates the effect of VAPOR water suppression and metabolite cycling on metabolite quantification and macromolecules in proton magnetic resonance spectroscopy.

Methods

Single‐voxel semi‐LASER spectra ( T R / T E = 3000/28 ms) and metabolite‐nulled spectra (macromolecules) were acquired in five healthy subjects in the posterior cingulate cortex at 3 T using two different water suppression schemes: VAPOR or metabolite cycling (MC). Post‐processed spectra were quantified using LCModel. Metabolites concentrations were compared between the two schemes.

Results

Region specific differences in macromolecule resonances were observed and the concentration of most metabolites was significantly higher when using MC compared to VAPOR. The difference was most pronounced for total creatine (−14% with VAPOR vs. MC, p < 0.05).

Conclusion

The macromolecules spectrum included in the LCModel basis set must be measured with the same water suppression scheme as the metabolite spectrum for accurate quantification.

Subjects

MeSH terms (MEDLINE)

WaterBrainProton Magnetic Resonance SpectroscopyHumansAdultMaleFemaleReproducibility of ResultsSensitivity and Specificity

Author keywords

VAPORbrainmetabolite cyclingsemi‐LASER

Substances

Water

Authors and institutions

  • Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.

ORCID profiles: Dinesh K Deelchand

Funding

  • NIBIB NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Deelchand, D. K., & Henry, P. G. (2026). Effect of Water Suppression and Metabolite Cycling on Quantification of 1 H MRS Spectra in the Human Brain at 3 Tesla. Magnetic Resonance in Medicine, 96(2), 542-547. https://doi.org/10.1002/mrm.70352

Vancouver

Deelchand DK, Henry PG. Effect of Water Suppression and Metabolite Cycling on Quantification of 1 H MRS Spectra in the Human Brain at 3 Tesla. Magnetic Resonance in Medicine. 2026;96(2):542-547. doi:10.1002/mrm.70352

BibTeX
@article{Deelchand2026,
  author = {Deelchand, Dinesh K and Henry, Pierre-Gilles},
  title = {Effect of Water Suppression and Metabolite Cycling on Quantification of 1 H MRS Spectra in the Human Brain at 3 Tesla},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {542--547},
  doi = {10.1002/mrm.70352}
}
Start for free →