EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Simultaneous Cerebral Blood Flow and Cerebrovascular Reactivity Obtained From Novel Multi‐Band Multi‐Echo Pseudo‐Continuous Arterial Spin Labeling ( M2 ‐ PCASL ) Sequence: A Test–Retest Reliability Study

Jody Todd iD, Maria-Julieta Mateos, Ibraheem Budeir, Deqiang Qiu

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70307 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2026. Written by Jody Todd and 3 co-authors. Institution: Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia, USA. Major MEDLINE topics: Cerebrovascular Circulation, Brain, Magnetic Resonance Imaging. 40 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIH HHS, National Institutes of Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

We aim to assess the reliability of cerebral blood flow (CBF) and cerebrovascular reactivity (CVR) obtained simultaneously from a novel multi‐band pseudo‐continuous arterial spin labeling (M2‐PCASL) sequence and hypercapnic gas challenge, to examine factors influencing CBF variability, and to evaluate the impact of carbon dioxide (CO 2 ) concentration on CVR estimates.

Methods

Nine participants underwent test–retest M2‐PCASL scans at 3T with hypercapnia to quantify CBF and CVR. Reliability was assessed using the intraclass correlation coefficient (ICC) at whole brain, region of interest (ROI), and voxel levels. Linear mixed‐effect models were used to investigate factors contributing to CBF variability. Independent samples t ‐tests were used to compare BOLD CVR and temporal contrast to noise ratio (tCNR) from different CO 2 concentrations.

Results

With smoothing, the M2‐PCASL sequence estimated baseline CBF and BOLD CVR with good to excellent reliability (ICC > 0.81) in the whole brain, gray matter (GM), and white matter (WM). Average ICCs across the Automated Anatomical Labeling atlas ROIs were between 0.50 ± 0.30 and 0.69 ± 0.19. CBF CVR achieved fair to moderate reliability in GM (ICCs between 0.42 and 0.55). Head motion was significantly associated with CBF temporal SNR ( p ≤ 0.002). 5% and 8% CO 2 yielded similar BOLD CVR estimates, but the BOLD tCNR using 5% CO 2 was lower, although not statistically significant.

Conclusion

The M2‐PCASL sequence with hypercapnia reliably estimates baseline CBF and BOLD CVR at improved spatial and temporal resolutions relative to existing methods, enabling us to noninvasively and comprehensively assess cerebrovascular health.

Subjects

MeSH terms (MEDLINE)

Cerebrovascular CirculationBrainMagnetic Resonance ImagingHumansReproducibility of ResultsSpin LabelsHypercapniaFemaleMaleAdultCarbon DioxideImage Processing, Computer-AssistedPerfusion Magnetic Resonance ImagingBlood Flow VelocityMagnetic Resonance AngiographyYoung Adult

Author keywords

arterial spin labelingblood oxygen level‐dependentcerebral blood flowcerebrovascular reactivitymulti‐bandmulti‐echo

Substances

Spin LabelsCarbon Dioxide

Authors and institutions

  • Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia, USA.
  • Georgia Institute of Technology, Atlanta, Georgia, USA.

ORCID profiles: Jody Todd

Funding

  • NIH HHS
  • National Institutes of Health

Cite

APA

Todd, J., Mateos, M. J., Budeir, I., & Qiu, D. (2026). Simultaneous Cerebral Blood Flow and Cerebrovascular Reactivity Obtained From Novel Multi‐Band Multi‐Echo Pseudo‐Continuous Arterial Spin Labeling ( M2 ‐ PCASL ) Sequence: A Test–Retest Reliability Study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70307

Vancouver

Todd J, Mateos MJ, Budeir I, Qiu D. Simultaneous Cerebral Blood Flow and Cerebrovascular Reactivity Obtained From Novel Multi‐Band Multi‐Echo Pseudo‐Continuous Arterial Spin Labeling ( M2 ‐ PCASL ) Sequence: A Test–Retest Reliability Study. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70307

BibTeX
@article{Todd2026,
  author = {Todd, Jody and Mateos, Maria-Julieta and Budeir, Ibraheem and Qiu, Deqiang},
  title = {Simultaneous Cerebral Blood Flow and Cerebrovascular Reactivity Obtained From Novel Multi‐Band Multi‐Echo Pseudo‐Continuous Arterial Spin Labeling ( M2 ‐ PCASL ) Sequence: A Test–Retest Reliability Study},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70307}
}
Start for free →