EUVIMEDEUVIMED entdecken
Crossref

Detection of inflammation in abdominal aortic aneurysm with reduced field-of-view and low-b-value diffusion-weighted imaging

Yi-Jun Pan, Xiao-Lang Jiang, Yan Shan, Peng-Ju Xu, Zhi-Hui Dong, Jiang Lin

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2024.110295 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Yi-Jun Pan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Zhongshan Hospital, Fudan University, No.180 Fenglin Road, Xuhui District, Shanghai 200032, China; Shanghai Institute of Med…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Diffusion Magnetic Resonance Imaging, Inflammation, Image Enhancement. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To evaluate the performance of diffusion-weighted imaging (DWI) with an optimal b-value and field-of-view in identifying wall inflammation in abdominal aortic aneurysm (AAA) by comparing it to delayed enhancement T1-weighted imaging (DEI). METHODS: Twenty-five males with AAA were prospectively enrolled and underwent fat-suppressed T1-weighted dark-blood imaging (T1WI), full field-of-view (f-FOV) and reduced field-of-view (r-FOV) DWI (b values = 0, 100, 400 and 800 s/mm2), and DEI. Corresponding images on f-FOV, r-FOV DWI and DEI at the same level were evaluated qualitatively and quantitatively using the paired t-test and Wilcoxon signed-rank test. The agreement in detecting wall inflammation between DWI and DEI sequences was analyzed using weighted kappa statistics. RESULTS: For both r-FOV and f-FOV DWI, the scores of delineation of aneurysm wall and lesion conspicuity, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were highest on DWI₁₀₀ (Ps < 0.05). The scores of delineation of aneurysm wall, geometric distortion, lesion conspicuity, and SNR, CNR were significantly higher on r-FOV DWI than those on f-FOV DWI (Ps < 0.05). r-FOV DWI₁₀₀ showed comparable performance to DEI in detecting wall inflammation (κ = 0.715), with superior blood suppression and higher SNR and CNR (Ps < 0.05). CONCLUSIONS: DWI with r-FOV and low b-value could be a promising alternative to DEI in identifying wall inflammation in AAA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, AbdominalDiffusion Magnetic Resonance ImagingInflammationImage EnhancementImage Interpretation, Computer-AssistedHumansMaleAgedMiddle AgedReproducibility of ResultsSignal-To-Noise RatioAged, 80 and overSensitivity and SpecificityProspective Studies

Stichwörter der Autor:innen

Abdominal aortic aneurysmDiffusion weighted imagingInflammationMagnetic resonance imaging

Autor:innen und Institutionen

  • Department of Radiology, Zhongshan Hospital, Fudan University, No.180 Fenglin Road, Xuhui District, Shanghai 200032, China; Shanghai Institute of Medical Imaging, No.180 Fenglin Road, Xuhui District, Shanghai 200032, Ch…
  • Department of Vascular Surgery, Zhongshan Hospital, Fudan University, No.180 Fenglin Road, Xuhui District, Shanghai 200032, China.

Zitieren

APA

Pan, Y. J., Jiang, X. L., Shan, Y., Xu, P. J., Dong, Z. H., & Lin, J. (2025). Detection of inflammation in abdominal aortic aneurysm with reduced field-of-view and low-b-value diffusion-weighted imaging. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.110295

Vancouver

Pan YJ, Jiang XL, Shan Y, Xu PJ, Dong ZH, Lin J. Detection of inflammation in abdominal aortic aneurysm with reduced field-of-view and low-b-value diffusion-weighted imaging. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2024.110295

BibTeX
@article{Pan2025,
  author = {Pan, Yi-Jun and Jiang, Xiao-Lang and Shan, Yan and Xu, Peng-Ju and Dong, Zhi-Hui and Lin, Jiang},
  title = {Detection of inflammation in abdominal aortic aneurysm with reduced field-of-view and low-b-value diffusion-weighted imaging},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2024.110295}
}
Kostenlos starten →