Designing B 1 ‐Selective Pulses by Frequency Modulating in a Second Rotating Frame
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70259 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Saurin Kantesaria und 7 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Algorithms, Image Enhancement, Brain. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NIH HHS, NIGMS NIH HHS.
Abstract (Originalsprache)
Purpose
To create a frequency‐modulated pulse for slice selection of arbitrary, uniform flip angle even when B 0 and B 1 are inhomogeneous, without utilizing B 0 gradients Theory and Methods An amplitude‐modulated hyperbolic secant pulse (AM HS1 ) was derived from Hoult's B 1 ‐selective imaging method which utilizes one component, B 1y , as a gradient and another, B 1x , for selective excitation. The frequency sweep in AM HS1 was produced by a time‐dependent amplitude‐modulation of B 1x , defining the band of nutation frequencies to select along the B 1y gradient. Resilience of slice selection to B 0 and B 1 inhomogeneities was investigated by simulations. Slice‐ and slab‐selective imaging were demonstrated experimentally in phantoms and rat brain in vivo using surface coils.
Results
Simulations of AM HS1 demonstrated slice inversion despite B 0 and B 1 inhomogeneities. When operating sub‐adiabatically to produce excitation flip angles < 180° with a single coil, the flip angle across the slice varied because both B 1x and B 1y gradients were present. This problem was corrected by scaling B 1x ( t ) by the normalized frequency‐sweep and phase‐modulation functions. Slice selection using only a B 1 gradient was demonstrated on phantoms using a pair of AM HS1 pulses transmitted with a surface coil. By using a low‐flip angle AM HS1 with B 1y refocusing lobes, slice‐ and slab‐selective excitation was realized in 3D gradient‐echo imaging of rat brain in vivo at 9.4 T.
Conclusion
By implementing frequency modulation in a second rotating frame, B 1 ‐selective excitation and inversion are feasible, even when B 0 and B 1 are nonuniform.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.
ORCID-Profile: Saurin Kantesaria, Mazin M Mustafa, Djaudat Idiyatullin, Gregor Adriany, Michael Garwood
Förderung
- NIBIB NIH HHS
- NIH HHS
- NIGMS NIH HHS
- National Institutes of Health
Zitieren
APA
Kantesaria, S., Torres, E., Mustafa, M. M., Idiyatullin, D., Ponticorvo, S., Adriany, G., Michaeli, S., & Garwood, M. (2026). Designing B 1 ‐Selective Pulses by Frequency Modulating in a Second Rotating Frame. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70259
Vancouver
Kantesaria S, Torres E, Mustafa MM, Idiyatullin D, Ponticorvo S, Adriany G, et al. Designing B 1 ‐Selective Pulses by Frequency Modulating in a Second Rotating Frame. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70259
BibTeX
@article{Kantesaria2026,
author = {Kantesaria, Saurin and Torres, Efraín and Mustafa, Mazin M and Idiyatullin, Djaudat and Ponticorvo, Sara and Adriany, Gregor and Michaeli, Shalom and Garwood, Michael},
title = {Designing B 1 ‐Selective Pulses by Frequency Modulating in a Second Rotating Frame},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70259}
}
EUVIMED