EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pole‐To‐Pole 3D Radial Trajectory Designs Improve Image Quality and Quantitative Parametric Mapping in the Brain and Heart

Eva S Peper, Grzegorz Bauman, Matteo Tagliabue iD, Berk C Açikgöz, Nils M J Plähn iD, Adèle L C Mackowiak, Yasaman Safarkhanlo iD, Joseph G Woods, Davide Piccini, Li Feng iD, Christopher W Roy, Oliver Bieri iD und 1 weitere

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70237 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Eva S Peper und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Heart. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To design 3D radial spiral phyllotaxis trajectories aimed at removing phase inconsistencies, improving image quality, and enhancing parametric mapping accuracy by acquiring nearly opposing spokes starting from both hemispheres in 3D radial k ‐space.

Methods

Two 3D radial trajectories, pole‐to‐pole and continuous spiral phyllotaxis, were developed and implemented on a 3T MRI scanner in a phase‐cycled balanced steady‐state free precession (bSSFP) and a spoiled gradient‐echo (GRE) sequence. Image quality and k ‐space center phase variations were evaluated in a spherical phantom using the original and new radial phyllotaxis designs. T1/T2 was quantified and compared using phase‐cycled bSSFP data acquired with the new radial trajectory designs, as well as the original phyllotaxis trajectory and a Cartesian trajectory as references, in both an MRI system phantom and the brains of three healthy volunteers. ECG‐triggered whole‐heart GRE data were acquired using the original and pole‐to‐pole phyllotaxis trajectories in three healthy volunteers and compared for image quality improvement.

Results

All 3D radial trajectory designs showed variations in the k ‐space center phase depending on the orientation of the readout spokes. Image quality improved when using the pole‐to‐pole and continuous phyllotaxis over the original trajectory. Scans using the original trajectory had higher T1/T2 estimation errors in comparison to the new trajectories and the Cartesian trajectory. The pole‐to‐pole and continuous trajectories improved T1/T2 maps of the brain and image quality for all cardiac images.

Conclusion

Acquiring nearly opposing spokes in 3D radial trajectory designs compensates phase inconsistencies without requiring additional corrections, which improves quantitative imaging and anatomical visualizations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainMagnetic Resonance ImagingImaging, Three-DimensionalHeartHumansPhantoms, ImagingAlgorithmsImage Processing, Computer-AssistedHealthy VolunteersReproducibility of ResultsAdult

Autor:innen und Institutionen

  • Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland.
  • Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, Switzerland.
  • Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
  • Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland.
  • Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

ORCID-Profile: Matteo Tagliabue, Nils M J Plähn, Yasaman Safarkhanlo, Li Feng, Oliver Bieri, Jessica A M Bastiaansen

Förderung

  • NIBIB NIH HHS
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Zitieren

APA

Peper, E. S., Bauman, G., Tagliabue, M., Açikgöz, B. C., Plähn, N. M. J., Mackowiak, A. L. C., Safarkhanlo, Y., Woods, J. G., Piccini, D., Feng, L., Roy, C. W., Bieri, O., & Bastiaansen, J. A. M. (2026). Pole‐To‐Pole 3D Radial Trajectory Designs Improve Image Quality and Quantitative Parametric Mapping in the Brain and Heart. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70237

Vancouver

Peper ES, Bauman G, Tagliabue M, Açikgöz BC, Plähn NMJ, Mackowiak ALC, et al. Pole‐To‐Pole 3D Radial Trajectory Designs Improve Image Quality and Quantitative Parametric Mapping in the Brain and Heart. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70237

BibTeX
@article{Peper2026,
  author = {Peper, Eva S and Bauman, Grzegorz and Tagliabue, Matteo and Açikgöz, Berk C and Plähn, Nils M J and Mackowiak, Adèle L C and Safarkhanlo, Yasaman and Woods, Joseph G and Piccini, Davide and Feng, Li and Roy, Christopher W and Bieri, Oliver and Bastiaansen, Jessica A M},
  title = {Pole‐To‐Pole 3D Radial Trajectory Designs Improve Image Quality and Quantitative Parametric Mapping in the Brain and Heart},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70237}
}
Kostenlos starten →