Self‐Supervised Joint Reconstruction and Denoising of T2 ‐Weighted PROPELLER MRI of the Lung at 0.55T

Jingjia Chen iD, Haoyang Pei iD, Christoph Maier, Mary Bruno, Qiuting Wen iD, Seon-Hi Shin, William Moore, Hersh Chandarana iD, Li Feng iD

Magnetic Resonance in Medicine · 2026-05 · 95 (5) · 2930-2946

DOI: 10.1002/mrm.70224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 12.12.2025. Verfasst von Jingjia Chen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New Yor…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Lung, COVID-19, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIBIB NIH HHS, NIDDK NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To improve 0.55T T2‐weighted PROPELLER lung MRI by developing a self‐supervised framework for joint reconstruction and denoising.

Methods

T2‐weighted 0.55T lung MRI datasets from 44 patients with prior COVID‐19 infection were used. Each PROPELLER blade was split along the readout direction into two disjoint subsets: one subset for training an unrolled network, and the other for loss calculation. Following the Noise2Noise paradigm, this framework split k‐space into two subsets with independent, matched noise but identical underlying signal, enabling joint reconstruction and denoising without external training references. For comparison, coil‐wise Marchenko‐Pastur Principal Component Analysis (MPPCA) denoising followed by parallel imaging reconstruction was performed. The reconstructed images were evaluated by two experienced chest radiologists.

Results

The self‐supervised model generated lung images with improved clarity, better delineation of parenchymal and airway structures, and maintained high fidelity in cases with available CT references. In addition, the proposed framework also enabled further reduction of scan time by reconstructing images with adequate diagnostic quality from only half the number of blades. The reader study confirmed that the proposed method outperformed MPPCA across all categories (Wilcoxon signed‐rank test, p < 0.001), with moderate inter‐reader agreement (weighted Cohen's kappa = 0.55; percentage of exact and within ±1 point agreement = 91%).

Conclusion

By leveraging the intrinsic data redundancy in PROPELLER sampling and extending the Noise2Noise concept, the proposed self‐supervised framework enabled simultaneous reconstruction and denoising of lung images at 0.55T to address the low‐SNR challenge at low‐field. It holds great potential for broad use in other low‐field MRI applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingLungCOVID-19Image Processing, Computer-AssistedHumansMaleFemaleSignal-To-Noise RatioMiddle AgedSARS-CoV-2AlgorithmsAgedAdultPrincipal Component AnalysisImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

PROPELLERdenoisinglow‐fieldlungreconstructionself‐supervised learning

Autor:innen und Institutionen

  • Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • Department of Electrical and Computer Engineering, New York University Tandon School of Engineering, New York, New York, USA.
  • Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, Indiana, USA.

ORCID-Profile: Jingjia Chen, Haoyang Pei, Qiuting Wen, Hersh Chandarana, Li Feng

Förderung

  • NIH HHS
  • NIBIB NIH HHS
  • NIDDK NIH HHS
  • Deutsche Forschungsgemeinschaft
  • National Institutes of Health

Zitieren

APA

Chen, J., Pei, H., Maier, C., Bruno, M., Wen, Q., Shin, S. H., Moore, W., Chandarana, H., & Feng, L. (2026). Self‐Supervised Joint Reconstruction and Denoising of T2 ‐Weighted PROPELLER MRI of the Lung at 0.55T. Magnetic Resonance in Medicine, 95(5), 2930-2946. https://doi.org/10.1002/mrm.70224

Vancouver

Chen J, Pei H, Maier C, Bruno M, Wen Q, Shin SH, et al. Self‐Supervised Joint Reconstruction and Denoising of T2 ‐Weighted PROPELLER MRI of the Lung at 0.55T. Magnetic Resonance in Medicine. 2026;95(5):2930-2946. doi:10.1002/mrm.70224

BibTeX
@article{Chen2026,
  author = {Chen, Jingjia and Pei, Haoyang and Maier, Christoph and Bruno, Mary and Wen, Qiuting and Shin, Seon-Hi and Moore, William and Chandarana, Hersh and Feng, Li},
  title = {Self‐Supervised Joint Reconstruction and Denoising of T2 ‐Weighted PROPELLER MRI of the Lung at 0.55T},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {95},
  number = {5},
  pages = {2930--2946},
  doi = {10.1002/mrm.70224}
}
Kostenlos starten →