High‐Accelerated Parallel Imaging With the Inherent Local Feature in PE ‐ xSPEN MRI
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70146 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Ke Dai und 7 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), School of Biomedical Engineer…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Medical-Engineering Interdisciplinary Research Fund of Shanghai Jiao Tong University, National Key Research and Development Program of China.
Abstract (Originalsprache)
Purpose
To achieve highly accelerated high‐resolution imaging with PE‐xSPEN that efficiently utilizes the spatiotemporal encoded signals to physically distinguish contributions from distinct spatial locations prior to k‐space acquisition, enabling the differentiation of aliased localized information in k‐space.
Methods
In the conventional k‐space, undersampling along the phase‐encoding dimension results in aliasing and overlapping replicas of the object along the spatial direction. The modulated hyperbolic phase arising from the PE‐xSPEN encoding induces coupling between the and dimensions. So that for a given k‐space location, the signal is predominantly contributed by local voxels. While undersampling along the PE dimension still causes aliased spatial replicas, these replicas remain distinguishable even without multi‐channel coils after applying the traditional inverse Fourier transform along the undersampled dimension. Combining with parallel imaging, this approach enhances unfolding efficiency compared to traditional Fourier‐encoded signals.
Results
Combining with GRAPPA, the undersampled signals along the dimension can be reconstructed with fewer residual aliasing in PE‐xSPEN compared to the traditional Fourier‐encoded signals. The performance gain is demonstrated by MRI simulation, phantom tests, and in vivo brain experiments on 3T scanner.
Conclusion
The proposed PE‐xSPEN GRAPPA framework utilizes hyperbolic phase modulation to control aliasing artifacts and generate ‐dependent coil response, reducing artifacts and noise amplification.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
- Faculty of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel.
- Department of Radiology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel.
ORCID-Profile: Philip K Lee, Yueqi Qiu, Lucio Frydman, Zhiyong Zhang
Förderung
- National Natural Science Foundation of China
- Medical-Engineering Interdisciplinary Research Fund of Shanghai Jiao Tong University
- National Key Research and Development Program of China
Zitieren
APA
Dai, K., Solomon, E., Lee, P. K., Tao, G., Qiu, Y., Chen, H., Frydman, L., & Zhang, Z. (2026). High‐Accelerated Parallel Imaging With the Inherent Local Feature in PE ‐ xSPEN MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70146
Vancouver
Dai K, Solomon E, Lee PK, Tao G, Qiu Y, Chen H, et al. High‐Accelerated Parallel Imaging With the Inherent Local Feature in PE ‐ xSPEN MRI. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70146
BibTeX
@article{Dai2026,
author = {Dai, Ke and Solomon, Eddy and Lee, Philip K and Tao, Guangyu and Qiu, Yueqi and Chen, Hao and Frydman, Lucio and Zhang, Zhiyong},
title = {High‐Accelerated Parallel Imaging With the Inherent Local Feature in PE ‐ xSPEN MRI},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70146}
}
EUVIMED