EUVIMEDEUVIMED entdecken
Crossref

Spin and Gradient Multiple Overlapping‐Echo Detachment Imaging ( SAGE ‐ MOLED ): Highly Efficient T 2 , T2*$$ {T}_2^{\ast } $$, and M 0 Mapping for Simultaneous Perfusion and Permeability Measurements

Qinqin Yang iD, Jianfeng Bao, Lu Wang, Nuowei Ge, Xiaoyue Ma, Shuhui Cai iD, Zhong Chen, Yong Zhang, Ali Gholipour, Congbo Cai

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Qinqin Yang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Science, Xiamen University, Xiamen, China. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Brain, Echo-Planar Imaging, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: National Key R & D Program of China, Science and Technology Project of Fujian Province of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Combined spin‐ and gradient‐echo EPI (SAGE‐EPI) offers advantages in tissue quantification and dynamic imaging but suffers from low spatial resolution and geometric distortions. This study aims to develop a multiple overlapping‐echo detachment‐based SAGE acquisition (SAGE‐MOLED) to enable efficient, distortion‐corrected T 2 , , and M 0 mapping for perfusion MRI.

Methods

SAGE‐MOLED was designed as an optimized MOLED variant by refining echo time sampling and integrating multi‐train blip‐reversed EPI to enhance distortion correction and temporal SNR, enabling reliable extraction of subject‐specific arterial input functions (AIFs). To support dynamic imaging, a steady‐state Bloch simulation‐based synthetic data framework was developed to simultaneously model T 1 , T 2 , and ‐related effects, providing training data for an end‐to‐end deep learning model that enables efficient multiparametric quantification. In addition, a signal‐to‐concentration model tailored for dynamic MOLED signals was formulated for accurate estimation of permeability and leakage‐corrected perfusion parameters. The proposed technique was validated in water phantom experiments, healthy volunteers, and a pilot clinical study.

Results

Single‐shot SAGE‐MOLED demonstrated high consistency with standard methods in both phantom and in vivo experiments, with Pearson correlation coefficient = 0.991 for T 2 and 0.988 for mapping in the brain. Compared to conventional SAGE‐EPI, SAGE‐MOLED mitigated geometric distortions and intravoxel dephasing‐related signal loss. In perfusion MRI, dynamic SAGE‐MOLED enabled simultaneous permeability and leakage‐corrected perfusion parameter estimation with a single‐dose contrast injection.

Conclusion

SAGE‐MOLED overcomes key limitations of SAGE‐EPI, providing high‐fidelity, distortion‐corrected T 2 , , and M 0 maps for simultaneous quantification of permeability and perfusion parameters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedBrainEcho-Planar ImagingMagnetic Resonance ImagingHumansAlgorithmsPhantoms, ImagingSignal-To-Noise RatioAdultMaleFemalePermeabilityComputer SimulationCerebrovascular Circulation

Stichwörter der Autor:innen

T 2 * $$ {T}_2^{\ast } $$ mappingDCEDSCMOLEDT2 mapping

Autor:innen und Institutionen

  • Department of Electronic Science, Xiamen University, Xiamen, China.
  • Department of Radiological Sciences, University of California Irvine, Irvine, California, USA.
  • Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, China.

ORCID-Profile: Qinqin Yang, Shuhui Cai

Förderung

  • National Key R & D Program of China
  • Science and Technology Project of Fujian Province of China
  • National Natural Science Foundation of China

Zitieren

APA

Yang, Q., Bao, J., Wang, L., Ge, N., Ma, X., Cai, S., Chen, Z., Zhang, Y., Gholipour, A., & Cai, C. (2026). Spin and Gradient Multiple Overlapping‐Echo Detachment Imaging ( SAGE ‐ MOLED ): Highly Efficient T 2 , T2*$$ {T}_2^{\ast } $$, and M 0 Mapping for Simultaneous Perfusion and Permeability Measurements. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70165

Vancouver

Yang Q, Bao J, Wang L, Ge N, Ma X, Cai S, et al. Spin and Gradient Multiple Overlapping‐Echo Detachment Imaging ( SAGE ‐ MOLED ): Highly Efficient T 2 , T2*$$ {T}_2^{\ast } $$, and M 0 Mapping for Simultaneous Perfusion and Permeability Measurements. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70165

BibTeX
@article{Yang2026,
  author = {Yang, Qinqin and Bao, Jianfeng and Wang, Lu and Ge, Nuowei and Ma, Xiaoyue and Cai, Shuhui and Chen, Zhong and Zhang, Yong and Gholipour, Ali and Cai, Congbo},
  title = {Spin and Gradient Multiple Overlapping‐Echo Detachment Imaging ( SAGE ‐ MOLED ): Highly Efficient T 2 , T2*$$ T_2^\ast  $$, and M 0 Mapping for Simultaneous Perfusion and Permeability Measurements},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70165}
}
Kostenlos starten →