EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Mitigating banding artifacts in balanced steady‐state free precession using parallel transmission in a single acquisition

Chia-Yin Wu iD, Jin Jin iD, Markus Barth iD, Martijn A Cloos iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70106 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Chia-Yin Wu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Advanced Imaging, The University of Queensland, St. Lucia, Queensland, Australia. Hauptthemen laut MEDLINE: Artifacts, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council Future Fellowship, Centre for Innovation in Biomedical Imaging Technology, Australian Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Using parallel transmission (pTx) in ultra‐high field MRI allows efficient radiofrequency pulse designs that can produce uniform excitations. Here, we demonstrate that pTx can simultaneously mitigate non‐uniformity and off‐resonance artifacts in balanced steady‐state free precession sequences at 7 T. Theory and Methods The standard hard excitation pulses of the balanced steady‐state free precession sequence were replaced with two pTx pulses, played out in alternating repetition times. Based on the k T ‐point trajectory, each pulse was designed to produce spatially varying phase distributions that compensate for off‐resonance phase variations accumulated over one repetition time duration, while also mitigating non‐uniformities. Depending on the local ΔB 0 , the different steady‐state signals formed were distributed over two aliased images with a half field‐of‐view shift relative to one another. Using slice‐GRAPPA, these images were disentangled and recombined to produce artifact‐free images.

Results

Simulations validated the concept showing that a pair of strategically designed pTx pulses can impose a favorable distribution of spatially varying steady‐state. As a proof of principle, experiments performed demonstrated the technical feasibility of the concept in a phantom in the presence of induced phase variations and in vivo.

Conclusion

With a tailored pair of pTx pulses, it was possible to concurrently mitigate and ΔB 0 non‐uniformities in a thin slab through the brain in a single acquisition. Although further work is needed to extend the coverage and robustness of this method before being adopted more widely, it highlights the potential of utilizing pTx capabilities beyond correction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsMagnetic Resonance ImagingImage Processing, Computer-AssistedPhantoms, ImagingHumansBrainAlgorithmsComputer SimulationRadio Waves

Stichwörter der Autor:innen

balanced SSFP (bSSFP)banding artifactparallel transmission (pTx)ultra‐high field

Autor:innen und Institutionen

  • Centre for Advanced Imaging, The University of Queensland, St. Lucia, Queensland, Australia.
  • ARC Training Centre for Innovation in Biomedical Imaging Technology, University of Queensland, St. Lucia, Queensland, Australia.
  • School of Electrical Engineering and Computer Science, University of Queensland, St. Lucia, Queensland, Australia.
  • Imaging Centre of Excellence, University of Glasgow, Glasgow, UK.
  • Siemens Healthineers Pty Ltd, Brisbane, Queensland, Australia.
  • Donders Centre for Cognitive Neuroimaging, Radboud University, Nijmegen, Netherlands.

ORCID-Profile: Chia-Yin Wu, Jin Jin, Markus Barth, Martijn A Cloos

Förderung

  • Australian Research Council Future Fellowship
  • Centre for Innovation in Biomedical Imaging Technology, Australian Research Council

Zitieren

APA

Wu, C. Y., Jin, J., Barth, M., & Cloos, M. A. (2026). Mitigating banding artifacts in balanced steady‐state free precession using parallel transmission in a single acquisition. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70106

Vancouver

Wu CY, Jin J, Barth M, Cloos MA. Mitigating banding artifacts in balanced steady‐state free precession using parallel transmission in a single acquisition. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70106

BibTeX
@article{Wu2026,
  author = {Wu, Chia-Yin and Jin, Jin and Barth, Markus and Cloos, Martijn A},
  title = {Mitigating banding artifacts in balanced steady‐state free precession using parallel transmission in a single acquisition},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70106}
}
Kostenlos starten →