Free‐breathing phase‐sensitive inversion recovery T 1 ‐weighted imaging for improved visualization of focal liver lesions
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70042 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2026. Written by Yavuz Muslu and 7 co-authors. Institution: Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA. Major MEDLINE topics: Magnetic Resonance Imaging, Liver Neoplasms, Image Enhancement, Image Interpretation, Computer-Assisted. 68 references. The full text is freely available (open access, CC BY 4.0). Funded by: GE Healthcare, Bayer HealthCare.
Abstract (original language)
Purpose
Gadoxetic acid‐enhanced hepatobiliary phase T 1 ‐weighted (T 1 w) MRI is effective for the detection of focal liver lesions but lacks sufficient T 1 contrast to distinguish benign from malignant lesions. Although the addition of T 2 , diffusion, and dynamic contrast‐enhanced T 1 w imaging improves lesion characterization, these methods often do not provide adequate spatial resolution to identify subcentimeter lesions. This work proposes a high‐resolution, volumetric, free‐breathing liver MRI method that produces colocalized fat‐suppressed, variable T 1 w images from a single acquisition, thereby improving both lesion detection and characterization. Theory and Methods This method combines stack‐of‐stars radial sampling, magnetization preparation, and chemical shift encoding to enable free‐breathing, T 1 w imaging with water/fat separation. A model‐based image reconstruction algorithm reconstructs images from highly undersampled k‐space data. Pseudo‐T 1 relaxation maps are calculated from the variable T 1 w images. The feasibility of this method was investigated in patients undergoing clinical contrast‐enhanced MRI examinations for detection and characterization of focal liver lesions at both 1.5 and 3.0 T. An expert reader study was conducted to evaluate the method's performance, compared with the hepatobiliary phase‐navigated T 1 w MRI based on image quality and lesion conspicuity.
Results
Expert readers found that at shorter inversion times (TIs) (˜500 ms), the proposed method had superior liver–lesion contrast for characterizing simple cysts and metastases, compared with navigated T 1 w images.
Conclusion
The proposed method produces colocalized fat‐suppressed, variable T 1 w images from a single acquisition that may improve focal liver lesion detection and characterization.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
- GE Healthcare, Waukesha, Wisconsin, USA.
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID profiles: Yavuz Muslu, Julius F Heidenreich, Jan-Peter Grunz, Ty A Cashen, Sagar Mandava, Ali Pirasteh, Diego Hernando, Scott B Reeder
Funding
- GE Healthcare
- Bayer HealthCare
Cite
APA
Muslu, Y., Heidenreich, J. F., Grunz, J. P., Cashen, T. A., Mandava, S., Pirasteh, A., Hernando, D., & Reeder, S. B. (2026). Free‐breathing phase‐sensitive inversion recovery T 1 ‐weighted imaging for improved visualization of focal liver lesions. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70042
Vancouver
Muslu Y, Heidenreich JF, Grunz JP, Cashen TA, Mandava S, Pirasteh A, et al. Free‐breathing phase‐sensitive inversion recovery T 1 ‐weighted imaging for improved visualization of focal liver lesions. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70042
BibTeX
@article{Muslu2026,
author = {Muslu, Yavuz and Heidenreich, Julius F and Grunz, Jan-Peter and Cashen, Ty A and Mandava, Sagar and Pirasteh, Ali and Hernando, Diego and Reeder, Scott B},
title = {Free‐breathing phase‐sensitive inversion recovery T 1 ‐weighted imaging for improved visualization of focal liver lesions},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70042}
}
EUVIMED