EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Navigator‐Based Slice Tracking for Multiband Accelerated Liver DWI

Ke Zhang iD, Simon M F Triphan, Congcong Fu, Na Zhang iD, Christian H Ziener, Mark E Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Oliver Sedlaczek

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 852-861

DOI: 10.1002/mrm.70354 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 24.03.2026. Verfasst von Ke Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic & Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Liver, Image Processing, Computer-Assisted, Image Interpretation, Computer-Assisted. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Clinical liver diffusion‐weighted imaging (DWI) suffers from long measurement time and respiratory motion. In this study, we employ a navigator‐based slice tracking technique (NAV) to prospectively compensate for respiratory motion in multiband (MB) accelerated liver DWI.

Methods

A single gradient‐echo slice readout at the location of the diaphragm along the inferior–superior direction was acquired as a navigator. Navigator acquisition and fat suppression were inserted before each transverse imaging slice of the readouts of a 2D spin‐echo EPI based DWI sequence, with 20 repeats including 32 training navigators (4 preparing scans) at the beginning of the measurement obtained in about 3 min. For comparison, MB accelerated DWI without NAV during free breathing was also acquired. To evaluate the effect of NAV on image quality, coefficients of variation (CoV), signal to noise ratio (SNR), and sharpness were calculated. Six healthy volunteers and three patients with lesions were examined at 1.5 T.

Results

The motion caused by respiratory activity was effectively computed using the navigator signal. For measurement with NAV, averaged CoV was significantly lower when compared to without NAV (0.256 ± 0.086 vs. 0.262 ± 0.091, p < 0.001). SNR and liver sharpness were also increased. The shapes of both kidney and spleen were continuous and smooth in the coronal view with NAV. Detailed structure in different organs could be found with NAV compared to without NAV in the cyst and tumor patients.

Conclusion

This study demonstrates the feasibility of a NAV technique to reduce respiratory motion in MB accelerated liver DWI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingLiverImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedLiver NeoplasmsHumansFemaleMaleAdultSignal-To-Noise RatioAlgorithmsMotionReproducibility of ResultsRespirationImage EnhancementArtifactsSensitivity and SpecificityMiddle Aged

Stichwörter der Autor:innen

liver diffusion weighted imagingnavigator‐based slice trackingprospective motion compensation

Autor:innen und Institutionen

  • Department of Diagnostic & Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany.
  • Translational Lung Research Center (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany.
  • Department of Diagnostic & Interventional Radiology With Nuclear Medicine, Thoraxklinik at Heidelberg University Hospital, Heidelberg, Germany.
  • Division of Radiology, German Cancer Research Center, Heidelberg, Germany.
  • Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • Division of Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany.

ORCID-Profile: Ke Zhang, Na Zhang

Zitieren

APA

Zhang, K., Triphan, S. M. F., Fu, C., Zhang, N., Ziener, C. H., Ladd, M. E., Schlemmer, H. P., Kauczor, H. U., & Sedlaczek, O. (2026). Navigator‐Based Slice Tracking for Multiband Accelerated Liver DWI. Magnetic Resonance in Medicine, 96(2), 852-861. https://doi.org/10.1002/mrm.70354

Vancouver

Zhang K, Triphan SMF, Fu C, Zhang N, Ziener CH, Ladd ME, et al. Navigator‐Based Slice Tracking for Multiband Accelerated Liver DWI. Magnetic Resonance in Medicine. 2026;96(2):852-861. doi:10.1002/mrm.70354

BibTeX
@article{Zhang2026,
  author = {Zhang, Ke and Triphan, Simon M F and Fu, Congcong and Zhang, Na and Ziener, Christian H and Ladd, Mark E and Schlemmer, Heinz-Peter and Kauczor, Hans-Ulrich and Sedlaczek, Oliver},
  title = {Navigator‐Based Slice Tracking for Multiband Accelerated Liver DWI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {852--861},
  doi = {10.1002/mrm.70354}
}
Kostenlos starten →