EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Abdominal simultaneous 3D water T 1 and T 2 mapping using a free‐breathing Cartesian acquisition with spiral profile ordering

Jonathan Stelter iD, Kilian Weiss, Lisa Steinhelfer, Jakob Meineke, Weitong Zhang, Bernhard Kainz, Rickmer F Braren, Dimitrios C Karampinos

Magnetic Resonance in Medicine · 2026-01 · 95 (1) · 268-285

DOI: 10.1002/mrm.70040 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2025-09-05. Written by Jonathan Stelter and 7 co-authors. Institution: Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich…. Major MEDLINE topics: Imaging, Three-Dimensional, Abdomen, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Cited 5 times so far (Crossref); 70 references. The full text is freely available (open access, CC BY 4.0). Funded by: Deutsche Forschungsgemeinschaft, TUM International Graduate School of Science and Engineering, Philips Healthcare.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

To develop a method for abdominal simultaneous 3D water () and () mapping with isotropic resolution using a free‐breathing Cartesian acquisition with spiral profile ordering (CASPR) at 3 T.

Methods

The proposed data acquisition combines a Look‐Locker scheme with the modified BIR‐4 adiabatic preparation pulse for simultaneous and mapping. CASPR is employed for efficient and flexible k‐space sampling at isotropic resolution during free breathing. The imaging pipeline includes subspace reconstruction, water‐fat separation, and ‐specific dictionary matching. The proposed method was validated in a water‐fat relaxometry phantom using spin echo‐based reference techniques and was compared with MOLLI and GRASE mapping in 10 volunteers. The method's flexibility was assessed at isotropic resolutions of 2.5, 3, and 3.5 mm, with corresponding scan times of 7:19, 5:23, and 3:52 min. Additionally, the method was applied to 9 oncological patients with abdominal pathologies.

Results

Phantom experiments demonstrated good agreement between the proposed method and spin echo‐based reference techniques across a wide range of and values. The volunteer study assessed in vivo quantification performance and demonstrated the flexibility of the proposed method at different spatial resolutions. The 3 mm method was successively performed in patients with abdominal pathologies, whereby lesions with diameters below 1 cm could be assessed.

Conclusion

The proposed Look‐Locker‐based method using CASPR enables efficient, flexible, and simultaneous and mapping at isotropic resolution in a fixed scan time during free breathing.

Subjects

MeSH terms (MEDLINE)

Imaging, Three-DimensionalAbdomenMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansPhantoms, ImagingAlgorithmsAdultRespirationMaleFemaleReproducibility of ResultsWater

Author keywords

Look‐Lockerisotropic resolutionliverrelaxometrywater‐fat separation

Substances

Water

Authors and institutions

  • Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
  • Philips GmbH Market DACH, Hamburg, Germany.
  • Philips Innovative Technologies, Hamburg, Germany.
  • Department of Computing, Imperial College London, London, UK.
  • Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Laboratory of Magnetic Resonance Imaging Systems and Methods, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.

ORCID profiles: Jonathan Stelter

Funding

  • Deutsche Forschungsgemeinschaft
  • TUM International Graduate School of Science and Engineering
  • Philips Healthcare
  • International Graduate School of Science and Engineering
  • Philips

Cite

APA

Stelter, J., Weiss, K., Steinhelfer, L., Meineke, J., Zhang, W., Kainz, B., Braren, R. F., & Karampinos, D. C. (2026). Abdominal simultaneous 3D water T 1 and T 2 mapping using a free‐breathing Cartesian acquisition with spiral profile ordering. Magnetic Resonance in Medicine, 95(1), 268-285. https://doi.org/10.1002/mrm.70040

Vancouver

Stelter J, Weiss K, Steinhelfer L, Meineke J, Zhang W, Kainz B, et al. Abdominal simultaneous 3D water T 1 and T 2 mapping using a free‐breathing Cartesian acquisition with spiral profile ordering. Magnetic Resonance in Medicine. 2026;95(1):268-285. doi:10.1002/mrm.70040

BibTeX
@article{Stelter2026,
  author = {Stelter, Jonathan and Weiss, Kilian and Steinhelfer, Lisa and Meineke, Jakob and Zhang, Weitong and Kainz, Bernhard and Braren, Rickmer F and Karampinos, Dimitrios C},
  title = {Abdominal simultaneous 3D water T 1 and T 2 mapping using a free‐breathing Cartesian acquisition with spiral profile ordering},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {95},
  number = {1},
  pages = {268--285},
  doi = {10.1002/mrm.70040}
}
Start for free →