EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Importance of R 2 accuracy in susceptibility source separation

Tereza Beatriz Oliveira Assunção iD, Nashwan Naji iD, Jeff Snyder iD, Peter Seres, Gregg Blevins, Penelope Smyth, Alan H Wilman

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70034 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2026. Written by Tereza Beatriz Oliveira Assunção and 6 co-authors. Institution: Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada. Major MEDLINE topics: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Cited 4 times so far (Crossref); 52 references. The full text is freely available (open access, CC BY 4.0). Funded by: Alberta Innovates, Natural Sciences and Engineering Research Council of Canada, CIHR.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

To examine the importance of R 2 accuracy on independent paramagnetic and diamagnetic outputs from susceptibility source separation in the brain from two publicly available methods.

Methods

The effects of R 2 errors, which translate into errors, on output maps from χ‐separation and χ‐sepnet were examined using data from 11 healthy volunteers. Baseline R 2 values were determined by Bloch modeling a dual‐echo turbo spin echo decay with measured flip angles. R 2 errors were introduced from either simple exponential fitting, R 2 multiplication factors, or R 2 approximation using only . Altered R 2 maps were then used as input for the susceptibility source separation models using either default or calculated relaxometric constant. Difference maps and mean percentage errors within regions of interest (ROIs) were measured.

Results

Errors in R 2 , and hence , directly affected paramagnetic and diamagnetic components. χ‐sepnet was less sensitive to R 2 errors than χ‐separation and had reduced variance among subjects. χ‐sepnet susceptibility component errors did not reach more than ±20% in most ROIs for all alteration approaches. In contrast, χ‐separation, with default relaxometric constant, reached 56% susceptibility component error with −25% R 2 error input. Exponential fitting R 2 error exceeded −25%, thus, even larger component errors occurred. ‐based approximation had −25% R 2 mean error across ROIs (−18% across whole brain), yielding 57% mean susceptibility component error across ROIs.

Conclusion

Paramagnetic and diamagnetic outputs of susceptibility source separation methods have variable responses to R 2 error, that may occur with simple R 2 fitting or R 2 approximation, and can be strongly biased by it.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingBrainImage Processing, Computer-AssistedHumansAdultMaleAlgorithmsFemaleReproducibility of ResultsBrain MappingHealthy Volunteers

Author keywords

R2 mapsource separationsusceptibilitytransverse relaxation mapping

Authors and institutions

  • Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
  • Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada.
  • Division of Neurology, Department of Medicine, University of Alberta, Edmonton, Alberta, Canada.

ORCID profiles: Tereza Beatriz Oliveira Assunção, Nashwan Naji, Jeff Snyder

Funding

  • Alberta Innovates
  • Natural Sciences and Engineering Research Council of Canada
  • CIHR
  • Canadian Institutes of Health Research

Cite

APA

Oliveira Assunção, T. B., Naji, N., Snyder, J., Seres, P., Blevins, G., Smyth, P., & Wilman, A. H. (2026). Importance of R 2 accuracy in susceptibility source separation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70034

Vancouver

Oliveira Assunção TB, Naji N, Snyder J, Seres P, Blevins G, Smyth P, et al. Importance of R 2 accuracy in susceptibility source separation. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70034

BibTeX
@article{OliveiraAssuno2026,
  author = {Oliveira Assunção, Tereza Beatriz and Naji, Nashwan and Snyder, Jeff and Seres, Peter and Blevins, Gregg and Smyth, Penelope and Wilman, Alan H},
  title = {Importance of R 2 accuracy in susceptibility source separation},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70034}
}
Start for free →