Importance of R 2 accuracy in susceptibility source separation
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70034 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Tereza Beatriz Oliveira Assunção und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alberta Innovates, Natural Sciences and Engineering Research Council of Canada, CIHR.
Abstract (Originalsprache)
Purpose
To examine the importance of R 2 accuracy on independent paramagnetic and diamagnetic outputs from susceptibility source separation in the brain from two publicly available methods.
Methods
The effects of R 2 errors, which translate into errors, on output maps from χ‐separation and χ‐sepnet were examined using data from 11 healthy volunteers. Baseline R 2 values were determined by Bloch modeling a dual‐echo turbo spin echo decay with measured flip angles. R 2 errors were introduced from either simple exponential fitting, R 2 multiplication factors, or R 2 approximation using only . Altered R 2 maps were then used as input for the susceptibility source separation models using either default or calculated relaxometric constant. Difference maps and mean percentage errors within regions of interest (ROIs) were measured.
Results
Errors in R 2 , and hence , directly affected paramagnetic and diamagnetic components. χ‐sepnet was less sensitive to R 2 errors than χ‐separation and had reduced variance among subjects. χ‐sepnet susceptibility component errors did not reach more than ±20% in most ROIs for all alteration approaches. In contrast, χ‐separation, with default relaxometric constant, reached 56% susceptibility component error with −25% R 2 error input. Exponential fitting R 2 error exceeded −25%, thus, even larger component errors occurred. ‐based approximation had −25% R 2 mean error across ROIs (−18% across whole brain), yielding 57% mean susceptibility component error across ROIs.
Conclusion
Paramagnetic and diamagnetic outputs of susceptibility source separation methods have variable responses to R 2 error, that may occur with simple R 2 fitting or R 2 approximation, and can be strongly biased by it.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada.
- Division of Neurology, Department of Medicine, University of Alberta, Edmonton, Alberta, Canada.
ORCID-Profile: Tereza Beatriz Oliveira Assunção, Nashwan Naji, Jeff Snyder
Förderung
- Alberta Innovates
- Natural Sciences and Engineering Research Council of Canada
- CIHR
- Canadian Institutes of Health Research
Zitieren
APA
Oliveira Assunção, T. B., Naji, N., Snyder, J., Seres, P., Blevins, G., Smyth, P., & Wilman, A. H. (2026). Importance of R 2 accuracy in susceptibility source separation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70034
Vancouver
Oliveira Assunção TB, Naji N, Snyder J, Seres P, Blevins G, Smyth P, et al. Importance of R 2 accuracy in susceptibility source separation. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70034
BibTeX
@article{OliveiraAssuno2026,
author = {Oliveira Assunção, Tereza Beatriz and Naji, Nashwan and Snyder, Jeff and Seres, Peter and Blevins, Gregg and Smyth, Penelope and Wilman, Alan H},
title = {Importance of R 2 accuracy in susceptibility source separation},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70034}
}
EUVIMED