Myocardial Arterial Spin Labeling with Double Inversion Recovery for reduced physiological noise
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.70018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Maša Božić-Iven und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands. Hauptthemen laut MEDLINE: Heart, Image Processing, Computer-Assisted, Magnetic Resonance Imaging. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Landesgraduiertenförderung Baden-Württemberg, 4TU Precision Medicine program supported by High Tech for a Sustainable Future, ZonMw.
Abstract (Originalsprache)
Purpose
To introduce Double Inversion Recovery (DIR) preparations for myocardial Arterial Spin Labeling (myoASL) for mitigation of heart rate (HR) variability induced physiological noise (PN).
Methods
DIR‐labeling was implemented for double ECG‐gated myoASL‐sequences and compared with conventional Flow‐sensitive Alternating Inversion Recovery (FAIR) labeling using single inversions. In DIR‐preparations, the FAIR‐inversion pulses were immediately followed by an identical reinversion pulse, applied either slice‐selectively or nonselectively. Bloch‐equation‐based simulation and phantom experiments were performed to evaluate the PN and SNR across a range of HR variabilities. Data from six healthy subjects were acquired to evaluate myocardial blood flow (MBF), PN, and SNR in vivo.
Results
Simulation experiments showed that the average MBF values remained nearly constant across the range of HR variabilities and were comparable across all three sequences. However, DIR‐labeling allowed for greater recovery of the myocardial background signal, which mitigates the sensitivity to HR‐dependent changes in the inversion time. Consequently, PN in the presence of HR variability was substantially reduced with DIR‐labeling. For HR variabilities corresponding to the mean value observed in vivo, this resulted in a simulated SNR gain of 1.79 0.90 for selective and 1.55 0.77 for nonselective DIR‐labeling. In vivo, DIR‐labeling showed reduced PN, with 53% ()/44% () less PN compared with conventional FAIR‐myoASL, leading to an average SNR gain of 1.47 0.63 ()/1.32 0.57 () with selective/nonselective reinversions.
Conclusion
The proposed DIR‐preparations reduce sensitivity to HR variations and alleviate PN in double ECG‐gated myoASL, improving the precision of myoASL‐based perfusion quantification.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
- Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Lausanne, Switzerland.
ORCID-Profile: Maša Božić-Iven, Stanislas Rapacchi, Yi Zhang, Qian Tao, Sebastian Weingärtner
Förderung
- Landesgraduiertenförderung Baden-Württemberg
- 4TU Precision Medicine program supported by High Tech for a Sustainable Future
- ZonMw
- Hartstichting
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
- European Research Council
Zitieren
APA
Božić-Iven, M., Rapacchi, S., Zhang, Y., Tao, Q., Schad, L. R., & Weingärtner, S. (2025). Myocardial Arterial Spin Labeling with Double Inversion Recovery for reduced physiological noise. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70018
Vancouver
Božić-Iven M, Rapacchi S, Zhang Y, Tao Q, Schad LR, Weingärtner S. Myocardial Arterial Spin Labeling with Double Inversion Recovery for reduced physiological noise. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.70018
BibTeX
@article{BoiIven2025,
author = {Božić-Iven, Maša and Rapacchi, Stanislas and Zhang, Yi and Tao, Qian and Schad, Lothar Rudi and Weingärtner, Sebastian},
title = {Myocardial Arterial Spin Labeling with Double Inversion Recovery for reduced physiological noise},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.70018}
}
EUVIMED