EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fast and High‐Resolution luminal water imaging for prostate cancer diagnosis

Hao Li iD, Nikita Sushentsev iD, Dimitri Kessler iD, Shaohang Li, Kang-Lung Lee, Andrew Nicholas Priest iD, Ferdia A Gallagher iD, Tristan Barrett

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30628 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Hao Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, People's Republic of China. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Magnetic Resonance Imaging. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Shanghai Municipal Science and Technology Explorer Project, NIHR Cambridge Biomedical Research Centre.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to address the limitation of long acquisition times in luminal water imaging (LWI), a promising noninvasive MRI technique for prostate cancer detection and grading, by implementing an accelerated multi‐echo spin‐echo method termed T2 mapping using echo merging plus k‐t undersampling with reduced flip angles ( TEMPURA) .

Methods

TEMPURA enables faster acquisition through echo merging, k ‐t undersampling, and reduced refocusing flip angles. A prospective study was conducted on 24 patients (age 59–75 years) with biopsy‐proven prostate cancer. Imaging was performed on a 3 T MRI system, comparing two TEMPURA‐based LWI sequences—Fast (standard resolution) and High‐Resolution (HR, doubled spatial resolution)—against a standard LWI sequence (Standard). Luminal water fraction and five additional parameters were compared across the methods. Statistical analyses included Spearman rank correlation, Wilcoxon rank sum test, receiver operating characteristic analysis, Bland–Altman plots, and Delong tests.

Results

Compared to Standard, Fast reduced the acquisition time from 8.3 to 2.8 min, whereas HR reduced it to 5.4 min and doubled spatial resolution. Both Fast and HR showed high correlation with Standard for luminal water fraction ( r = 0.97/0.90 in peripheral zone, r = 0.91/0.93 in transition zone), with low bias (0.014/0.018 in peripheral zone, 0.024/0.024 in transition zone) and no significant differences ( p = 0.05–0.84/0.08–0.51). No significant difference was observed in area under the curve values between Fast/HR and Standard among all parameters ( p = 0.05–0.87).

Conclusion

The acceleration method greatly reduced the acquisition time and increased the spatial resolution of LWI. Compared with the Standard acquisition, both the Fast and HR methods showed a high correlation for LWI measurements and consistent diagnostic performance in detecting malignant lesions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostatic NeoplasmsMagnetic Resonance ImagingHumansMaleAgedMiddle AgedProspective StudiesWaterProstateImage Interpretation, Computer-AssistedAlgorithmsReproducibility of ResultsImage Processing, Computer-AssistedROC Curve

Stichwörter der Autor:innen

imaging accelerationluminal water imagingmulticomponent T2multi‐echo spin‐echoprostate MRI

Substanzen

Water

Autor:innen und Institutionen

  • Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, People's Republic of China.
  • Department of Radiology, University of Cambridge, Cambridge, United Kingdom.
  • Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan.
  • School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
  • Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, United Kingdom.

ORCID-Profile: Hao Li, Nikita Sushentsev, Dimitri Kessler, Andrew Nicholas Priest, Ferdia A Gallagher

Förderung

  • National Natural Science Foundation of China
  • Shanghai Municipal Science and Technology Explorer Project
  • NIHR Cambridge Biomedical Research Centre
  • Cambridge Experimental Cancer Medicine Centre
  • the Engineering and Physical Sciences Research Council Imaging Centre in Cambridge and Manchester
  • Cancer Research UK

Zitieren

APA

Li, H., Sushentsev, N., Kessler, D., Li, S., Lee, K. L., Priest, A. N., Gallagher, F. A., & Barrett, T. (2025). Fast and High‐Resolution luminal water imaging for prostate cancer diagnosis. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30628

Vancouver

Li H, Sushentsev N, Kessler D, Li S, Lee KL, Priest AN, et al. Fast and High‐Resolution luminal water imaging for prostate cancer diagnosis. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30628

BibTeX
@article{Li2025,
  author = {Li, Hao and Sushentsev, Nikita and Kessler, Dimitri and Li, Shaohang and Lee, Kang-Lung and Priest, Andrew Nicholas and Gallagher, Ferdia A and Barrett, Tristan},
  title = {Fast and High‐Resolution luminal water imaging for prostate cancer diagnosis},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30628}
}
Kostenlos starten →